Accessing Plex Manager status views
If you are not in BMC AMI Ops
- Start a terminal session by performing one of the following actions:
- Execute the BMC AMI Ops CLIST from the COMMAND line: TSO EX ' hilevel.UBBSAMP(MainView)'
Start a VTAM or EXCP Alternate Access terminal session that executes the BMC AMI Ops CLIST.
- Select option P for Plex Manager. The EZPLEX menu is the default view that appears first when you access Plex Manager from the Selection Menu.
- On the EZPLEX menu, position the cursor on one of the following Target Activity fields and press Enter:
- Sum by Area for the PLEXAREA view
- Sum by Product for the PLEXPROD view
- Sum by System/Prod for the PLEXOVER view
- Not Summarized for the PLEX view
If you are in another BMC AMI Ops product that is running in windows mode
Use the following CONtext command:
CON * PLEXMGR; viewName
If you are currently displaying a Plex Manager view
Enter viewName on the COMMAND line.
The following figures are examples of the PLEX and PLEXOVER status views.
PLEX view
COMMAND ===>
CURR WIN ===> 1 ALT WIN ===>
<W1 =PLEX==============MVSDPV71=*========16JUN2023==09:03:22====PLEXMGR==D====8=========
C Product Server Default Ver Rel Mod RSL Lvl CEC Name Sysplex z/OS Job
- -------- -------- View --- --- --- --- -------- -------- ------- Sysname- Name----
MVEXP MVE11971 EZEXP 7 1 0 RSL2101 FALCON BMCPLEX1 SJSD MVSDVEXT
MVEXP MVE02222 EZEXP 7 1 0 RSL2101 FALCON BMCPLEX1 SJSD BITDVETT
MVEXP MVE02301 EZEXP 7 1 0 RSL2110 FALCON BMCPLEX1 SJSC BITDVEXL
MVEXP MVE11971 EZEXP 7 1 0 RSL2110 FALCON BMCPLEX1 SJSC MVSDVEXY
MVEXP MVE01809 EZEXP 7 1 0 RSL2110 FALCON BMCPLEX1 SJSC BITDVEXG
PLEXMGR PLEXMGR EZPLEX 7 1 0 RSL2101 FALCON BMCPLEX1 SJSD BBM71CTT
PLEXMGR PLEXMGR EZPLEX 7 1 0 RSL2110 FALCON BMCPLEX1 SJSC BBM71CDC
PLEXMGR PLEXMGR EZPLEX 7 0 0 BMCPLEX1 SJSD BBM70CDC
PLEXOVER view
COMMAND ===> SCROLL ===> PAGE
CURR WIN ===> 1 ALT WIN ===>
>W1 =PLEXOVER==========SJSC=====*========18JUN2018==06:50:54====PLEXMGR==D===51
C Context Product Description Status Server
- -------- -------- --------------------------------------- ------- --------
BCDQ MVMQS MainView for MQ Active X28D
CICSC700 MVCICS SJSC-MVCICS-X28C Active X28C
CICSD700 MVCICS SJSC-MVCICS-X28D Active X28D
CICSD700 MVVP SJSC-MVCICS-X28D Active X28D
CSQ4 MVMQS MainView for MQ Active X28D
CSQ5 MVMQS MainView for MQ Active X28C
CSQ6 MVMQS MainView for MQ Active X28C
CSQ8 MVMQS MainView for MQ Active X28D
DEDDX28D MVDB2 X28D-DEJP Active X28D
DEDDX28D MVVP X28D-DEJP Active X28D
DEEN MVDB2 X28C-DEEN Active X28C
DEJA MVDB2 X28D-DEJA Active X28D
DEJA MVVP X28D-DEJA Active X28D
DJP2 MVDB2 X28C-DJP2 Active X28C
GRT1 MVMQS MainView for MQ Active X28C
SJSC CMF CMF MONITOR Online Active XTS2
SJSC MVALERT Alert Manager Active M28C
In each of these views, the Context field shows the name of the target context that is recognized by the CAS. The Status field shown to the right of the view indicates whether monitoring is active.
For more information about these views, hover over the view name shown on the window information line and press the Help key. Help is also available for the fields on these views. Hover over a field and press the Help key to get a description of the field.