Limited supportBMC provides limited support for this version of the product. As a result, BMC no longer accepts comments in this space. If you encounter problems with the product version or the space, contact BMC Support.BMC recommends upgrading to the latest version of the product. To see documentation for that version, see BMC AMI Ops Infrastructure 7.1 .

Working with Alarm Management parameter files


The default initialization groups for Alarm Management are controlled by the alarm parameter file that tells how Alarm Management is started or initialized.

Each alarm parameter file contains the following information:

  • Whether to start the alarm manager in CAS or not, Yes or No.
  • Whether to list the names of the active alarm definitions during the alarm manager initialization, Yes or No.
  • Whether the names of the alarm definitions being activated should be written to the console during the alarm manager initialization.
  • The names of the groups to be automatically processed when Alarm Management is started in the CAS. System symbols can be used in the specification of group names.

From the ALPARML view, you can perform the following alarm parameter file actions:

  • Add a new alarm parameter file.
  • Change an alarm parameter file.
  • Delete an alarm parameter file.
  • Display the content of an alarm parameter file.
  • Deploy an alarm parameter file. 

To create an alarm parameter file

  1. On the EZALARMS menu, select Alarm Parameters under Other to open the ALPARML view. The ALPARML view displays a list of the alarm parameter files sorted by name.

    ALPARML view

    ddmmmyyyy  hh:mm:ss ------ BMC AMI Ops WINDOW INTERFACE (Vv.r.mm) ----------------
    COMMAND  ===>                                                 SCROLL ===> PAGE
    CURR WIN ===> 1        ALT WIN ===>                                             
    >W1 =ALPARML===========CXTSTW===*========ddmmmyyyy==hh:mm:ss====PLEXMGR==D====7
    CMD ParmFile Description                              Modified Modified        
    --- Name---- -----------                              by------ YYYY-MM-DD HH:MM
        ALPRM01  Test Parameter File 1                    BITKCY4  2005/04/26 17:57
        ALPRM02  Test Parameter File 2                    RDAPQF   2005/05/19 14:20
        ALPRM03  Test Parameter File 3                    BITKCY3  2004/11/04 15:53
        ALPRM04  Test Parameter File 4                    BITKCY3  2004/11/04 17:12
        ALPRM05  Test Parameter File 5                    BITKCY4  2005/04/26 18:11
        ALPRM06  Test Parameter File 6                    BITKCY4  2005/04/26 16:41
        ALPRM07  Test Parameter File 7                    BITKCY4  2005/04/26 18:10
  2. Type A in the CMD column or type ADD on the COMMAND line, and press Enter to open the Add a New Alarm Parameter File dialog.

    Tip

    • If you want to create a parameter file that is based on the contents of an existing parameter file use the A line command on the line of the model parameter file.
    • If you want to create a new parameter file starting from scratch, use the ADD COMMAND line command.

    (BMC.AMIOPS.SPE2201)

                          Add a New Alarm Parameter File  
    COMMAND ===>                                              SCROLL ===> CSR    
                                                                                
                                                                                
     Alarm Parameter Name:                                                      
     Start Alarm Mgmt in CAS: Yes       (Yes or No)                             
     List Alarm Definitions:  Yes       (Yes or No)                             
     Description:             Enter description here                            
                                                                               
    Groups to Activate at Initialization                                        
    Type group name(s) or type ? and press Enter for list     
     ________________  ________________  ________________  ________________
     ________________  ________________  ________________  ________________
     ________________  ________________  ________________  ________________
     ________________  ________________  ________________  ________________
     ________________  ________________  ________________  ________________


    END to create the parm file
    CANCEL to return to the ALPARML view
    ENTER to refresh data
    HELP to view related help                                        
  3. Specify the required information for your alarm parameter file: 

    Field

    Description

    Alarm Parameter Name

    Name of the alarm parameter

    Start Alarm Mgmt in CAS (Yes or No)

    Whether to start Alarm Management in the CAS

    List Alarm Definitions (Yes or No)

    Whether to list alarm definitions

    Description

    Brief description of the alarm

    Groups to Activate at Initialization

    Name of the group or groups to activate at initialization

    You can type the group names, or (BMC.AMIOPS.SPE2201) you can type ? and press Enter to see a list of existing alarm groups. For more information, see Step 4.

    If you specify the name of a group that doesn't exist, message BBMAPA25 instructs you to correct the group name.

  4. (BMC.AMIOPS.SPE2201)

    (If you specified ? for Groups to Activate at Initialization), take the following steps:

    1. On the Select Alarm Group for Auto Activation dialog, type S next to the alarm groups that you want to activate at initialization. 

                        Select Alarm Group for Auto Activation  
      COMMAND ===>                                              SCROLL ===> CSR   
                                                                          MORE: +  
      Set the alarm group from the list of existing alarm groups                  
                                                                                  
      Select one or more alarm groups (in TSO use line command S)                 
                                                                                 
        Alarm Group                                                               
        ------------------------                                                 
      S DEFAULT                                                                   
      S GRPCICS                                                                   
      _ GRPDB2                                                                    
      S GRPIMS                                                                    
      _ GRPMQS                                                                    
      _ GRPMVS                                                                    
                                                                                  
      END to select the groups and return                                          
      CANcel to exit without selecting the groups                                  
      HELP to go to help                                                           

      Tip

      You can see a description of the fields on the dialog be pressing F1 or typing HELP on the COMMAND line and pressing Enter.

    2. Press End.
      The Add a New Alarm Parameter File dialog is displayed with the selected group names.
  5. Press End to create your new parameter file.

To edit an alarm parameter file

  1. On the EZALARMS menu, select Alarm Parameters under Other to open the ALPARML view.
  2. Type in the CMD column of the parameter file you want to edit.
  3. Press Enter to open the Update Alarm Parameter File dialog.
  4. Specify the required information for your alarm parameter file, and press End to save the changes to your parameter file.

To delete an alarm parameter file

  1. On the EZALARMS menu, select Alarm Parameters under Other to open the ALPARML view.
  2. Type D in the CMD column of the parameter file you want to delete.
  3. Press Enter to open the Delete Alarm Parm File Confirmation dialog.
  4. Press End to confirm the deletion of the alarm parameter file.

To display alarm parameter file changes

Logger records changes to the alarm parameter files.

On the EZALARMS menu, select Alarm Param Actions under Activity Log to open the APMODLOG view.

To deploy an alarm parameter file

Note

Each target system must be at version 6.3.00 of BMC AMI Ops Infrastructure and have PTF BQY2220 applied.

  1. On the EZALARMS menu, select Alarm Parameters under Other to open the ALPARML view.
  2. Type T in the CMD column of one or more parameter files you want to deploy.
  3. Type the DEPloy primary command on the COMMAND line.
  4. Press Enter.
  5. Complete the deployment wizard (see Using-the-alarm-deployment-feature).
    The deployment process starts and the DEPYMNT view is displayed showing the status of the request.




 