Information
Limited support BMC provides limited support for this version of the product. As a result, BMC no longer accepts comments in this space. If you encounter problems with the product version or the space, contact BMC Support.BMC recommends upgrading to the latest version of the product. To see documentation for that version, see BMC AMI Ops Infrastructure 7.1 .

IRSYNCH parameter


The optional IRSYNCH parameter specifies how many minutes into the hour to offset the recording interval set by the IRRI parameter.

This parameter uses the following syntax:

IRSYNCH=[ 0|nn|QTR|HALF|HOUR]

Possible values are as follows:

  • 0 (the default, which records data as specified by the IRRI parameter)
  • nn (any value between 1 and 60 minutes)
  • QTR (15 minutes)
  • HALF (30 minutes)
  • HOUR (60 minutes)

For example, assume that IRSYNCH=8 and IRRI=15. Data recording begins 8 minutes after the hour and recurs every 15 minutes, as follows (where xx represents the hour):

  • xx:08:00
  • xx:23:00
  • xx:38:00
  • xx:53:00

These parameter settings can impact all products running in the BBI-SS PAS that process interval record data. Use the BBI Control command .D P (Display Products) to display the list of active products in a BBI-SS PAS.

Warning

Note

You can specify different IRSYNCH values for different BBI-SS PASs. When you retrieve historical interval data from these PASs, the display contains data from different interval boundaries for the same MVI TIME interval.