TOM system REXX stem variables for GET


The following table lists variables (and example values) that are returned after issuing the TOMEXEC GET function for TOM system records (TOMSYSTEM).

Some variables are index variables and their value is the number of occurrences of the variable that have been returned. That index number becomes a node within the variable name for the specific values for each variable. Any variable that contains an n as a node in the variable name also has an index variable.

REXX stem variables and sample values: TOM system GET

REXX stem variable

Description of variable

Examples of values

LINE.NAME

TOM ID

TOM23A

LINE.TOMPLEX

TOMPLEX TOM is currently a member of

TOMPROD

LINE.SYSPLEX

SYSPLEX that TOM runs on

SYSPLEXA

LINE.MANAGE

TOM object management (NORMAL, SUSPEND)

SUSPEND

LINE.EVAL

TOM evaluation requests (NORMAL, SUSPEND)

NORMAL

LINE.JOINTOD

Time of day when TOM PAS last joined the TOMPLEX

CDBDB93E9238EE53

LINE.ENDTOD

Time of day when TOM PAS last joined the TOMPLEX

CDBDB93FA349BB63

LINE.IPLTOD

Time of day when TOM PAS ended

CDBD3E7837E12E5A

LINE.SYSNAME

IBM z/OS system name were TOM PAS runs

SYSA

LINE.SYSVER

Version of IBM z/OS system where TOM PAS runs

01

LINE.SYSREL

Release of IBM z/OS system where TOM PAS runs

13

LINE.SYSMOD

Modification level of IBM z/OS system where TOM PAS runs

00

LINE.LPARNAME

LPAR name where TOM PAS runs

SYSA

LINE.CLONEID

Clone ID of system where TOM PAS runs

SA

LINE.SMFID

SMF ID of system where TOM PAS runs

SYSA

LINE.PASNAME

Product address space name

TOM23PAS

LINE.CASNAME

Coordinating address space name that the TOM PAS uses

MVICAS61

LINE.IPLLEVEL

Target IPLLEVEL

NETWORK

LINE.IPLLVLO

IPLLEVEL status (ENABLED or DISABLED)

DISABLED

LINE.ACTODB

Active object Definition Base

DEFAULT

LINE.ACTCDB

Active calendar Definition Base

DEFAULTCAL

LINE.REGOWNR

Registry owner (YES or NO)

YES

LINE.OMODE

Operation mode specified at TOM PAS start after IPL

DISASTER

LINE.OPERNOTE.0

Number of operator command note entries

2

LINE.OPRNOTE.n.CMD

Command associated with operator note

Only one note per command is kept for an object. When a specific command (such as SHUTSYS) is issued a second time with a note, the previous note for that command is overwritten.

SYSTEM SHUTLOCK

LINE.OPRNOTE.n.USER

Specifies the user ID to be used to create the operator command note

PRDOPR1

LINE.OPRNOTE.n.TOD

Date and time that operator command note was written in EBCDIC format

D17D28A5165842CA

LINE.OPRNOTE.n.TEXT

Text of operator command note

System Shutdown

LINE.AOSSID

SSID of the BMC AMI Ops Automation PAS that the TOM PAS uses

AOSS

LINE.RGYDSN

Registry data set name in use by the TOMPLEX

TOM23.TOMPROD.REGISTRY

LINE.STATUS

TOM current status (INACTIVE, INITIALIZING, READY, TERMINATING)

READY

LINE.NAME

Name of the Definition Base

PROD_OBJ_BASE

LINE.DESCR

Definition Base description

Production DefBase

LINE.UPDATED.TOD

Time-of-day the Definition Base was last updated by an administrator

CD738D38C0E8FC5A

LINE.UPDATED.USERID

User-id of the last administrator that updated the Definition Base

TOMADM1


 

Tip: For faster searching, add an asterisk to the end of your partial query. Example: cert*