TARGET PROFILE SELECTION panel


This section describes how to define individual profiles.

Use the TARGET PROFILE SELECTION panel to define individual profiles for up to 23 targets plus a default target.

To create a new profile for an undefined z/OS target, follow these steps:

  1. Change the TGT system name on the SYSTEM STATUS panel to the target name for which you want to create a profile.
  2. Enter the primary command TARGETS on the COMMAND line and press Enter.

The following shows an example of the TARGET PROFILE SELECTION panel.

BMC Software ------------ TARGET PROFILE SELECTION -----------------------------
COMMAND ===>
                                                             DATE --- YY/MM/DD
                                                             TIME --- 15:42:27

  Profiles are defined for these Target Systems.
  LINE COMMANDS: (S)elect, (D)elete

   LC   TARGET              LC   TARGET              LC   TARGET
   ___  MNVB                ___  -OPEN-              ___  -OPEN-
   ___  SYSB                ___  -OPEN-              ___  -OPEN-
   ___  -OPEN-              ___  -OPEN-              ___  -OPEN-
   ___  -OPEN-              ___  -OPEN-              ___  -OPEN-
   ___  -OPEN-              ___  -OPEN-              ___  -OPEN-
   ___  -OPEN-              ___  -OPEN-              ___  -OPEN-
   ___  -OPEN-              ___  -OPEN-              ___  XXXX
   ___  -OPEN-              ___  -OPEN-              ___  DEFAULT


Press END to save

You can enter the following commands in the LC column of this display:

Line command

Description

S

Use S (select) to select an -OPEN- slot for use by the z/OS target system (shown in the TGT field of the System Status application

D

Use D (delete) to make the indicated system profile slot available for use and remove the target from the profile

After you assign a slot for a target, press PF3 to display the SYSTEM STATUS PROFILE screen. You can now modify the SYSTEM STATUS PROFILE panel to create your profile.

Warning

Note

You cannot delete (D) a currently active target from this panel. You also cannot assign a target system twice.

 

Tip: For faster searching, add an asterisk to the end of your partial query. Example: cert*

BMC AMI Ops Automation 8.4