Restarting IBM CICS target regions


To complete the implementation of BBI-SS PAS to CICS communication, perform the following steps:

  1. Start each BBI-SS PAS that will communicate with a CICS region (if it is not already active).

  2. Restart each already active CICS region that will communicate with a BBI-SS PAS. 
  3. For each CICS region that communicates with a BBI-SS PAS but for which the procedure in Step 4: Modify the PLT was not performed, manually start BBI-SS PAS-to-CICS communication; use either the SMN2 transaction from within the CICS region or the FST2 transaction from the z/OS console.See Manual-activation-of-BBI-SS-to-CICS-communication for more information.

  4. Ensure that the following messages are issued from each CICS region that will communicate with a BBI-SS PAS:

    +FT431I   SESSION WITH BBI-SS XXXX ESTABLISHED
    +FT806I AutoOPERATOR for CICS initialization started
    +FT803I CICS TRANSIENT DATA INTERCEPT STARTED
    +BCA900I  OLTSCAO9 started for INIT processing with transaction ID BMCA
    +BCA901I  Ready to process key 9 TDQ messages
    +FT809I AutoOPERATOR for CICS initialization complete

    The implementation of BBI-SS PAS to CICS communication is now complete.

 

Tip: For faster searching, add an asterisk to the end of your partial query. Example: cert*