Starting and stopping the SERVICE REFRESH CYCLE
To start the cycle
Enter the GO command (F6/18).
To stop the cycle
Press the attention interrupt key (ATTN for SNA terminals and PA1 for non-SNA terminals).When the cycle stops, the last display shown is reissued and returned to the screen in INPUT mode.
You can analyze the status and make additional requests for other displays as usual. When you press F3, the display returns to the SERVICE REFRESH CYCLE application and shows the service names, parameters, and any short messages.
To restart the cycle
Press F6 or type GO to restart the cycle.Each refreshed service display is shown in the sequence and time (DTIME) specified. For the example shown in Creating-cyclic-displays-with-CYCLE-SETUP, the IMF MFSUT application is displayed first, followed by the BMC AMI Ops Monitor for Db2 DUSER application, the DA application of the BMC AMI Ops Automation for z/OS option, and the BMC AMI Ops Monitor for CICS FILE application. The cycle repeats again, starting with IMF MFSUT.