Newer version of documentation BMC provides a newer version of the documentation for this version of the product. As a result, BMC no longer accepts comments in this space.BMC recommends upgrading to the latest version of the product. To see documentation for that version, see bao8301.

SYSINFO function


Use the SYSINFO function to request and receive information (in variables) about all TOM PASs that are running on a MVS system, regardless of the TOMPLEX to which the MVS system belongs.

When the TOMEXEC SYSINFO function is specified, the following REXX stem variables are returned:

  • TOM.0 represents the number of TOM PASs that were found.
  • TOM.n represents the ID of the TOM PAS.
  • TOMXCF.n represents the name of the TOMPLEX to which the TOM belongs.
  • TOMVER.n represents the release version of the TOM PAS.

The following table shows the command and parameter:

Command

Parameters

TOMEXEC FUNCTION(SYSINFO)

TOMPLEX(tomplex name)

The following table describes the parameter:

Parameter

Function

TOMPLEX

Specify the name of the TOMPLEX to which the TOM belongs when you want to restrict the search to a specific group name.

For example, if you want to find only TOMs belonging to the default BMCTOM group name, specify:

TOMPLEX(BMCTOM).

This section contains the following topics:

 

Tip: For faster searching, add an asterisk to the end of your partial query. Example: cert*