Newer version of documentation BMC provides a newer version of the documentation for this version of the product. As a result, BMC no longer accepts comments in this space.BMC recommends upgrading to the latest version of the product. To see documentation for that version, see bao8301.

Logger


TOM uses the 

Logger

 to write records to the default MVLOGGER 

BMC AMI Ops

 LOG. The use of the 

Logger

 is optional for TOM and TOM messages are written to the TOM PAS job log and the z/OS system log when the 

Logger

 is not active.

See Administering for information about the Logger.

TOM distributes a log reporting utility MAMLXRPT that allows you to select specific records from the BMC AMI OpsLOG and to specify individual fields to extract from each of the selected records. BBSAMP member MAMLXRPT formats the extracted fields into columns and writes those formatted columns of the selected records to a sequential data set.

Along with the SELECT and WHERE control cards in the SYSIN DD, you can specify the FROM control card to indicate from which Logger (and its logspace) on the system to obtain the messages:

FROM(SSID=logger-ssid,LSPACEID=iiiiiiii)

where

  • logger-ssid is the value of the Logger BBIPARM LOGGERxx member LOGSSID parameter
  • iiiiiiii is the value of the Logger BBIPARM LOGGERxx member LOGSPACE parameter.

Note

The Logger has a default parameter setting of 3 for the MAXPERSEC parameter in BBPARM member LOGGER00. There are times when TOM activity can result in messages that come at a higher rate than the default setting. When this occurs, it is possible that not all of the messages are written out to the Logger and that all audit messages, or TOM debugging messages might not appear.

The documentation for the utility is in the sample JCL included in BBSAMP member MAMLXRPT.

Related topic

 

Tip: For faster searching, add an asterisk to the end of your partial query. Example: cert*