Specifying collection intervals
In this step, specify the collection interval (in minutes) for the Automation Reporter to collect data. For example, if you specify 60, then every 60 minutes the Automation Reporter will record the data in the subsystem for the resources and activities.
Valid collection interval values
Valid collection intervals range from 10 minutes to 1440 minutes. The default is 15 minutes.
To specify the collection interval, in the Interval field of the Automation Reporter Parms panel, enter the collection interval as shown in the following figure.
COMMAND ===> TGT --- MS@1
DATE --- YY/MM/DD
TIME --- 13:39:59
Member Current
New DSN ===> AAOAO.SAVE.ARSTATS
Current ===
Disp ===> MOD Dataset disposition (SHR, MOD)
Interval ===> 60 Interval minutes (10 - 1440, or 0)
Off int ===> 1440 Offload interval minutes (60 - 1440)
Alert Queue ===> MAIN Alert Queue
Press END to save changes, CANCEL to cancel changes
In this example, the interval is specified as 60 minutes. Therefore, after this DPM member is activated, every hour the Automation Reporter records the data as it exists at the end of the interval.
The data is not available to be browsed until it is offloaded into the data set.
Proceed to Specifying-the-offload-interval.
Related topic