How to activate the Automation Reporter
Activation of the Automation Reporter is accomplished through the
BMC AMI Ops Automation
application Dynamic Parameter Manager.
The Dynamic Parameter Manager (DPM) is a panel-driven application that allows you to view or modify parameters in BBPARM members from a BBI-TS session.
The BBPARM members currently supported by DPM are as follows:
BBPARM member name | Description |
---|---|
AAOEXPxx | BMC AMI OpsA EXEC-related parameters |
AAOALSxx | BMC AMI OpsA ALERT thresholds |
AAOARPxx | Parameters for the Automation Reporter |
AAOTSPxx | Parameters for BMC AMI Ops Automation TapeSHARE |
The AAOARPxx member is the one that controls the Automation Reporter and it is where you specify information such as
Time interval at which the Automation Reporter is to record data about automation resources and activities
Offload interval which determines how often the collected data is moved to a preallocated sequential data set
Name of the preallocated sequential data set that the collected data is moved to
You must preallocate a sequential data set and enter its name into DPM. At the offload interval, the collected data is written into this data set.
Disposition of the sequential data set
You can specify whether the sequential data set you allocated is going to have a disposition of MOD or SHR.
BMC AMI OpsA ALERT queue name where Automation Reporter ALERTs are queued
Any BMC AMI OpsA ALERTs generated by the Automation Reporter will be routed automatically to the ALERT queue name you specify here.
For more information about activating the Automation Reporter and specifying these parameters, refer to Starting-the-Automation-Reporter.