/* DOC GROUP(MVS) FUNC(MONITORS)  CODE(MN)                                  */
/* DOC DISP(YES) AUTHOR(B&B)                                                */
/* DOC DESC(RESOLVE WTO BUF SHORTAGE)                                       */
/*--------------------------------------------------------------------------*/
/* NAME:                                                                    */
/*      IEE249I                                                             */
/*                                                                          */
/* DESCRIPTION:                                                             */
/*      RESOLVE THE WTO BUFFER SHORTAGE SITUATION                           */
/*                                                                          */
/* SEE ALSO:                                                                */
/*      IEA404A                                                             */
/*      IEA405E                                                             */
/*                                                                          */
/* INVOKED BY:                                                              */
/*      IEA404A                                                             */
/*      IEA405E                                                             */
/*                                                                          */
/* INPUT PARAMETERS:                                                        */
/*      NONE                                                                */
/*                                                                          */
/* OUTPUT:                                                                  */
/*      NONE                                                                */
/*                                                                          */
/* OUTBOARD CALLS:                                                          */
/*      NONE                                                                */
/*                                                                          */
/* EXTERNAL ROUTINES CALLED:                                                */
/*      MVS 'K' OR 'Control' COMMANDS ARE ISSUED.                           */
/*      NOTE: FOR THE 'K' COMMANDS TO BE PROPERLY AUTHORIZED, THEY MUST BE  */
/*      ----  ISSUED FROM A NON-SUBSYSTEM CONSOLE.  EDIT THE MEMBER,        */
/*            BBISSP00, IN YOUR BBPARM DATA SET AND ADD THE KEY WORD,       */
/*            CMDCON=1; THIS WILL DIRECT ALL COMMANDS WHICH DO NOT REQUIRE  */
/*             A RESPONSE TO CONSOLE ID 1.                                  */
/*                                                                          */
/* ALERTS ISSUED:                                                           */
/*      NONE                                                                */
/*                                                                          */
/* VARIABLES USED:                                                          */
/*      NAME:       DESCRIPTION:          DEFAULT VALUE:                    */
/*      MSG         MESSAGE ID            IEE249I                           */
/*      P1          WORD 1                CUA OF CONSOLE OR SYSLOG          */
/*      P2          WORD 2                CONSOLE ID                        */
/*      P3          WORD 3                COND=                             */
/*      P4          WORD 4                AUTH=                             */
/*      P5          WORD 5                NBUF=                             */
/*                                                                          */
/* TEST SCRIPT INFO:                                                        */
/*      GENERATE A WTO FROM A TEST EXEC TO TRIGGER A CALL TO EITHER OF      */
/*      THE DRIVER EXECS: IEA404A OR IEA405E                                */
/*                                                                          */
/* RETURN CODES:                                                            */
/*      NONE                                                                */
/*                                                                          */
/* CHANGE LOG:                                                              */
/*      03-05-90 BY MDR: ADDED DOCUMENTATION BOX                              */

The information contained at the top of the documentation box is used by the BMC AMI OpsA EXEC Management Application to display information about the EXECs in the SYSPROC libraries. GROUP, FUNC, CODE, DISP, AUTHOR, and DESC are displayed on one line by the BMC AMI OpsA EXEC Management Application (see to Using-Rules-with-BMC-AMI-Ops-Automation for more information). The rest of the information in the documentation box is for self-documentation and easy reference.

The following table describes the documentation box fields.

Field

Description

GROUP

group to which this EXEC belongs (for example, MVS, CICS, DB2 , or IMS)

FUNC

functional category within the group

CODE

two-character function code

DISP

whether information about this EXEC should be displayed under the EXEC Management Application (refer to Using-Rules-with-BMC-AMI-Ops-Automation)

AUTHOR

author of the EXEC

DESC

description of what the EXEC does (25 characters or fewer)

NAME

name of the EXEC

DESCRIPTION

detailed description of what the EXEC does

SEE ALSO

cross-reference listing

INVOKED BY

list of other EXECs that call this one

INPUT PARAMETERS

parameter name, description, and default value required for input parameters

OUTPUT

information or names of variables that are returned

OUTBOARD CALLS

whether any pager calls have been placed

EXTERNAL ROUTINES CALLED

other routines or services called, along with any special considerations for those calls

ALERTS ISSUED

brief text of long EXECs where ALERTs are issued; otherwise, a YES or NO is returned

VARIABLES USED

variable name, description, and default value of any variables used

TEST SCRIPT INFO

necessary environment and steps that are needed to test the EXEC if changes are required

RETURN CODES

what return codes (if any) are returned

CHANGE LOG

chronology of changes


 