Restart Only objects


Question: How does Restart Only Control = Y work?

Answer: When an object is defined to CSM with the Restart Only Control field set to Y (yes), CSM does not start it automatically during IPL. The object is started and stopped externally by other means (console command, scheduler, and so on).

After it has been started the first time, the Restart Only Control=Y setting means CSM will control restarts for this object only if the object terminates unscheduled.

 