Newer version of documentation BMC provides a newer version of the documentation for this version of the product. As a result, BMC no longer accepts comments in this space.BMC recommends upgrading to the latest version of the product. To see documentation for that version, see bao8301.

MVS console considerations


MVS commands can be issued by 

BMC AMI Ops Automation

 terminal session (TS) users, EXECs, or Rules. When MVS commands are issued by TS users and from EXECs, the TS user or the EXEC can also wait for and inspect the response from the command.

Extended MCS (EMCS) consoles allow BMC AMI OpsA to issue MVS command and inspect the responses from these commands.

The use of consoles is not a consideration for MVS commands issued from Rules because BMC AMI OpsA Rules never expect a response. However, some commands issued by TS users and EXECs require a response to the command and therefore, require a MVS console.

For more information about how EXECs use consoles, refer to the Using-advanced-automation-with-BMC-AMI-Ops-Automation where the IMFEXEC CMD statement is documented.

This section includes the following topics:

 