Changing the RESTORE parameter
Use the following procedure to change the RESTORE parameter.
From the master console, issue the following command:
/F <masterPas>,RESTORE=<option>Possible values for option are:
Option
Description
YES (the default)
Restores DCs and GCLs to the values they had when the master PAS initialized.
NO
Leaves DCs and GCLs as they were when iCap stopped managing the LPAR or group, or the PAS terminated.
ZERO
Sets DCs to 0 and GCLs to the value they had when the PAS initialized.
ENT
Sets the DC and GCL values based on entitlement:
- For LPARs, iCap sets the DC according to the LPAR's entitlement level.
- For groups, iCap sets the GCL according to the group's entitlement level.
For group members that are being managed individually, iCap sets the GCL to the sum of the individual members' entitlements.
Restores DCs and GCLs to the values defined for each LPAR or group in the policy
If you specify RESTORE=POL, you must also specify DC and GCL values for all of the LPARs and groups in the policy. For more information see the description of the restore parameter in LPAR-level-and-group-level-parameters.
For more information, see iCap-PAS-started-task-parameters.