Creating an Automator populate event



Use the following procedure to create an Automator populate event.

Before you begin

Warning

Important

This procedure assumes that you have already configured or know how to configure a 32-bit ODBC system data source, and that you have added it to the Automator catalog. For more information about how to create an OBDC data source, see Knowledge Base on the BMC Support Central site.

To create an Automator populate event

  1. Run the Automator application.The application will be found in the Start Menu underBMC AMI Capacity Management.

  2. Select File > New.
    A new script window is displayed.
  3. Select Edit > Add Target Database/Group.
  4. From the list, select the ODBC Database from which you want to populate the data to, and click OK.
  5. Select Edit > Add Event > Populate.
  6. Browse or enter a location on the local machine to which you want to transfer the VIS files.
  7. Click OK.
    Your script should now look as follows:

    GUID-71874028-34B5-4B01-AED4-410CF4E7F9A4-low.png

    If you run the Automator populate event now and you have VIS files in the specified folder, they should populate to the designated database.



 

Tip: For faster searching, add an asterisk to the end of your partial query. Example: cert*