EXCP count
For VSAM data sets, EXCP Count shows the number of I/O operations performed on the data set during the measurement session. Because Strobe derives VSAM counts from the samples taken during the measurement session, they may not match the EXCP counts recorded by SMF.
For non-VSAM data sets, this value represent the number of blocks of data transferred during the measurement session, not the number of physical I/O operations performed on the data set.
For concatenated data sets on the same volume, EXCP counts appear in the entry for the first data set within the concatenation.
For data sets in the Hierarchical File System (HFS), EXCP counts are collected only if STROBEfor UNIX System Services is installed at your site.
Related topic
Tip: For faster searching, add an asterisk to the end of your partial query. Example: cert*