Messages Returned by the Strobe History Manager
The Strobe History Manager returns the following messages.
STR1800E SYSTEM SERVICE FAILED (sysserve) ddname - RC=rc ERC=erc
Explanation: The system service sysserve for ddname ddname failed. The return code is rc, and the reason code, if given, is erc.
System Action: The history manager may terminate.
User Response: Notify the Strobe system programmer.
STR1801E CREATE INTERNAL ERROR - HGWA ALREADY EXISTS
Explanation: A duplicate call was made to build a history global work area (HGWA).
System Action: The history manager terminates.
User Response: Contact Compuware Customer Support.
STR1802E fnctname INTERNAL ERROR - HGWA DOES NOT EXIST
Explanation: A function fnctname failed because Strobe could not find a history global work area (HGWA) control block.
System Action: The history manager terminates.
User Response: Contact Compuware Customer Support.
STR1803E fnctname - ddname DATA SET NOT OPERATIONAL
Explanation: While executing function fnctname, Strobe found the dataset that ddname ddname refers to is not operational.
System Action: The history manager terminates.
User Response: Contact Compuware Customer Support.
STR1804E fnctname - ddname ENVIRONMENT NOT ESTABLISHED
NOSVT - Strobe environment not established
Explanation: Strobe attempted to use the dataset referred to by DDNAME ddname without first building the necessary control blocks. The function name that detected the error is fnctname.
The NEW/CHANGED PROGRAM list batch utility program requires that Strobe must be active in order to process the request. If Strobe is not active, the second format of this message will be issued.
System Action: The requested Strobe process terminates.
User Response: Contact Compuware Customer Solutions.
STR1805E OPEN - ddname DATA SET ALREADY OPEN
Explanation: Strobe attempted to open the dataset that ddname ddname refers to and found that it was already opened.
System Action: The history manager terminates.
User Response: Notify the Strobe system programmer.
STR1806E fnctname - ddname HGWA CORRUPTION DETECTED
Explanation: While processing a call for function fnctname and ddname ddname, Strobe detected history global work area (HGWA) corruption.
System Action: The history manager terminates.
User Response: Contact Compuware Customer Support.
STR1807E fnctname - ddname DATA SET NOT OPEN
Explanation: Strobe function fnctname found that the dataset that ddname ddname refers to was already closed.
System Action: The history manager terminates.
User Response: Contact Compuware Customer Support.
STR1808E fnctname - ddname PLIST MISSING OR INVALID
Explanation: While processing a call for function fnctname and ddname ddname, Strobe found that the parameter list was missing or invalid.
System Action: The history manager terminates.
User Response: Contact Compuware Customer Support.
STR1809E fnctname - ddname QPL POINTER INVALID AT address
Explanation: While processing function fnctname for ddname ddname, Strobe found that the history parameter list pointer at address addr was invalid.
System Action: The history manager terminates.
User Response: Contact Compuware Customer Support.
STR1810S ddname DATASET NOT ALLOCATED
Explanation: During startup, Strobe determined that the dataset that ddname ddname refers to was missing. Strobe requires that this dataset be allocated.
System Action: The history manager terminates.
User Response: Ask the Strobe system programmer to correct the history manager JCL and restart the history manager.
STR1811S OSER - ddname RESERVE ALREADY OUTSTANDING
Explanation: Strobe attempted to issue two reserves for the same history dataset that ddname ddname refers to.
System Action: The history manager terminates.
User Response: Contact Compuware Customer Support.
STR1812S fnctname - ddname RESERVE NOT ISSUED
Explanation: In the function fnctname, Strobe attempted to open the dataset that ddname ddname refers to without first reserving it.
System Action: The history manager terminates.
User Response: Contact Compuware Customer Support.
STR1813W OPEN - ddname VSAM OPEN STATUS RC=rc RSN=rsn
Explanation: Strobe determined that the dataset that ddname ddname refers to was not properly closed and that VSAM has performed an implicit VERIFY. The VSAM return code is rc, and the VSAM reason code is rsn.
System Action: Strobe continues processing normally.
User Response: Notify the Strobe system programmer.
STR1814E OPEN - ddname UNABLE TO INITIALIZE DATA SET RC=rc
Explanation: Strobe was unable to complete the initialization of the dataset that ddname ddname refers to. The VSAM return code is rc.
System Action: The history manager terminates.
User Response: Contact Compuware Customer Support.
STR1815E fnctname - failingfnct ddname STATUS RC=rc RSN=rsn
Explanation: A function, failingfnct, failed for the dataset that ddname ddname refers to. The return code of the failed function is rc, and the reason code of the failed function is rsn. fnctname is the function currently executing.
System Action: The history manager terminates.
User Response: Contact Compuware Customer Support.
STR1816E DD FIND - ddname DDNAME INVALID
Explanation: The ddname referred to by ddname is invalid.
System Action: The history manager terminates.
User Response: Contact Compuware Customer Support.
STR1817E DD FIND - ddname DSNAME TABLE POINTER INVALID AT addr
Explanation: Strobe found that the dataset table pointer in the ddname table referred to by ddname is invalid at address addr.
System Action: The history manager terminates.
User Response: Contact Compuware Customer Support.
STR1818E ddname - DATASET IS FULL
Explanation: The dataset identified in ddname is full.
System Action: If you receive this message while producing Performance Profile reports, Strobe will produce the reports, but no history information will be added to the history database. If you receive this message while accessing Strobe/ISPF panels to add a measurement session history or cost record, the measurement session history record will not be added to the database.
User Response: Notify the Strobe system programmer. As a temporary measure, you may delete unneeded measurement session history records from the history dataset. The Strobe system programmer can allocate a larger history dataset and use the IDCAMS utility to copy information from the previous history dataset to the newly created history dataset.
STR1819I HISTORY DATA SET STRUCTURES REMOVED
Explanation: Strobe disabled the history file processing.
System Action: Strobe continues processing.
User Response: None required.
STR1820E STRH INTERNAL ERROR. ERROR CODE = erc
Explanation: Strobe encountered an error while attempting to access the history database. The error code is given in erc.
System Action: If this error occurred while producing Performance Profile reports, Strobe will produce reports but no history information will be added to the history database. If this error occurred while you were accessing or modifying the history database through Strobe/ISPF, the history database will be disabled.
User Response: If the problem persists, contact Compuware Customer Support.
STR1821E DATASTORE ENVIRONMENT NOT ESTABLISHED
Explanation: The system resources required for the history data temporary storage area are not available.
System Action: If this error occurred while producing Performance Profile reports, Strobe will produce reports but no history information will be added to the history database. If this error occurred while you were accessing or modifying the history database using Strobe/ISPF, the history database will be disabled.
User Response: If the problem persists, contact Compuware Customer Support.
STR1822E DATASTORE FUNCTION FAILED: errortext
Explanation: Strobe encountered an error accessing a temporary storage area. The reason for the error is described in errortext.
System Action: If this error occurred while producing Performance Profile reports, Strobe will produce reports but no history information will be added to the history database. If this error occurred while you were accessing or modifying the history database using Strobe/ISPF, the history database will be disabled.
User Response: If the problem persists, contact Compuware Customer Support.
STR1823W STRHLOG NOT ALLOCATED. LOGGING DISABLED
Explanation: The message log file for measurement session history collection and reporting has not been allocated.
System Action: Strobe will not write messages to the history log, but all other measurement session history collection and reporting will continue normally.
User Response: Allocate a log file for measurement session history collection and reporting and resubmit the request.
STR1824W ERROR {OPENING | CLOSING} STRHLOG. LOGGING DISABLED
Explanation: Strobe encountered an error attempting to open or close the log file for measurement session history collection and reporting.
System Action: Strobe will not write messages to the history log, but all other measurement session history collection and reporting will continue normally.
User Response: Notify the Strobe system programmer.
STR1825W INCORRECT DCB OPTIONS FOR STRHLOG. LOGGING DISABLED
Explanation: The DCB parameters for the history log file are not correct.
System Action: Strobe will not write messages to the history log, but all other measurement session collection and reporting will continue normally.
User Response: Review the instructions for allocating the history log file described in the Installation-and-Configuration-Guide and reallocate the dataset.
STR1826W SWAREQ FAILED. RC=rc. LOGGING DISABLED
Explanation: A call to an MVS service, SWAREQ, failed. Log functions will not operate.
System Action: Strobe continues processing, but there will be no history log.
User Response: Notify the Strobe system programmer.
STR1827W fnctname FOR STRHLOG FAILED. LOGGING DISABLED
Explanation: Function fnctname for log processing failed. The history log is disabled.
System Action: Strobe continues processing, but there will be no history log.
User Response: Notify the Strobe system programmer.
STR1828W STRHLOG I/O ERROR ENCOUNTERED. SENSE BYTES: xxx STATUS BYTES yyyy. LOGGING DISABLED
Explanation: An I/O error occurred while processing the history log.
System Action: Strobe continues processing but will not process history log information.
User Response: Notify the Strobe system programmer.
STR1829E STORAGE ALLOCATION FAILED
Explanation: An attempt to obtain storage allocation failed.
System Action: All Strobe measurement session history collection and reporting is disabled.
User Response: Notify the Strobe system programmer.
STR1830W ABEND IN LOG PROCESSING. LOGGING DISABLED.
Explanation: Strobe experienced an ABEND processing log functions.
System Action: Strobe continues processing, but there will be no history log.
User Response: Notify the Strobe system programmer.
STR1831E RECOVERY ENVIRONMENT COULD NOT BE ESTABLISHED. RETURN CODE rc. REASON CODE reascode
Explanation: Strobe could not establish a recovery environment.
System Action: All Strobe measurement session history collection and reporting is disabled.
User Response: Notify the Strobe system programmer.
STR1832E Strobe CANNOT WRITE TO {STRHPRNT | STRHEXPT} FILE STATUS ##
Explanation: Strobes attempt to write to either the print file (STRHPRNT) or the export file (STRHEXPT) failed. The file status is ##.
System Action: Strobe continues processing but will not print or export the measurement session history record.
User Response: Contact the Strobe system programmer.
STR1833E INVALID CALL TO {PRINT | EXPORT}, DATASTORE IS datastore
Explanation: While processing datastore datastore, Strobe received an illegal call to either the print or export function.
System Action: Strobe continues processing but the measurement session history record will not be printed or exported.
User Response: Contact the Strobesystem programmer.
STR1834E EMPTY DATASTORE PASSED TO {EXPORT | PRINT | COMPARE}
Explanation: A call was made to either the export, print, or compare function, but the datastore contained no data.
System Action: Strobe continues processing, but will not export or print the measurement session history record, or compare it to the baseline value.
User Response: Contact the Strobe system programmer.
STR1835S ERROR - DEFAULT COST PARM MISSING/INVALID
Explanation: The first parameter in the SYSIN dataset for the cost record installation program was not ‘DEFAULTCOST=(‘
System Action: The cost record installation program terminates.
User Response: Correct the SYSIN dataset and rerun the program.
STR1836S ERROR - INVALID PARM INPUT
Explanation: Either the last character in the parameter field was not a right parenthesis ‘)’ or a blank record was entered in the SYSIN dataset.
System Action: The cost record installation program terminates.
User Response: Correct the SYSIN dataset and rerun the program.
STR1837S ERROR - INCONSISTENT INPUT DATA
Explanation: A service unit parameter was combined with CPU and I/O cost parameters. When you initialize cost records, you can use either service units costs or CPU and I/O costs, but not both.
System Action: The cost record installation program terminates.
User Response: Correct the SYSIN dataset and rerun the program.
STR1838S ERROR LOADING HISTORY MANAGER
Explanation: The cost record installation program was unable to locate the history manager component.
System Action: The cost record installation program terminates.
User Response: Review the Strobe history manager instructions in the Installation-and-Configuration-Guide and verify that the appropriate Strobe libraries are loaded. If the problem persists, contact Compuware Customer Support.
STR1839S ERROR - INVALID PRIME CPU COST ENTRY
Explanation: PRIMECPU data is not in the form nnnnn.nn.
System Action: The cost record installation program terminates.
User Response: Correct the SYSIN dataset and rerun the program.
STR1840S ERROR - INVALID PRIME IO COST ENTRY
Explanation: PRIMEIO data is not in the form nnnnnn.nnn.
System Action: The cost record installation program terminates.
User Response: Correct the SYSIN dataset and rerun the program.
STR1841S ERROR - INVALID PRIME SU COST ENTRY
Explanation: PRIMESU data is not in the form nnnnn.nnn.
System Action: The cost record installation program terminates.
User Response: Correct the SYSIN dataset and rerun the program.
STR1842S ERROR - INVALID/MISSING PRIME TIME START ENTRY
Explanation: PRIMESTART data is missing or not in the form nnnn.
System Action: The cost record installation program terminates.
User Response: Correct the SYSIN dataset and rerun the program.
STR1843S ERROR - INVALID/MISSING PRIME TIME END ENTRY
Explanation: PRIMEEND data is missing or not in the form nnnn.
System Action: The cost record installation program terminates.
User Response: Correct the SYSIN dataset and rerun the program.
STR1844S ERROR - INVALID NONPRIME CPU COST ENTRY
Explanation: NONPRIMECPU data is not in the form nnnnn.nn.
System Action: The cost record installation program terminates.
User Response: Correct the SYSIN dataset and rerun the program.
STR1845S ERROR - INVALID NONPRIME IO COST ENTRY
Explanation: NONPRIMEIO data is not in the form nnnnnn.nnn.
System Action: The cost record installation program terminates.
User Response: Correct the SYSIN dataset and rerun the program.
STR1846S ERROR - INVALID NONPRIME SU COST ENTRY
Explanation: NONPRIMESU data is not in the form nnnnn.nnn.
System Action: The cost record installation program terminates.
User Response: Correct the SYSIN dataset and rerun the program.
STR1847S ERROR - INVALID PARM VALUE - parmvalue
Explanation: An invalid parameter value, parmvalue, was entered in the SYSIN dataset.
System Action: The cost record installation program terminates.
User Response: Correct the SYSIN dataset and rerun the program.
STR1848E DELETE FAILED. RECORD BEING ACCESSED BY ANOTHER USER
Explanation: The DELETE request failed because another user is accessing this record.
System Action: Strobe does not process the request.
User Response: Retry the DELETE request when the record is not being used.