Messages Returned by Strobe for CA Gen
Strobe for CA Gen returns the following messages.
STR2926C ACTION DIAGRAM SUMMARY REPORT EXCEEDED LIMITS
Explanation: An internal table has overflowed.
System Action: Strobe produces the Action Diagram Summary report; however, the information in the report is incomplete.
User Response: Notify the Strobe system programmer.
STR2927C AD-DET-TABLE OVERFLOWED FOR ACTION DIAGRAM action diagram
Explanation: The AD-DET-TABLE table overflowed.
System Action: Strobe does not produce an Action Diagram Statement report for the action diagram action diagram.
User Response: Notify the Strobe system programmer.
STR2928C AD-STMT-TABLE OVERFLOWED FOR ACTION DIAGRAM action diagram
Explanation: The AD-STMT-TABLE table overflowed.
System Action: Strobe does not produce an Action Diagram Statement report for the action diagram action diagram.
User Response: Notify the Strobe system programmer.
STR2929C NO DIAGRAM SAMPLED OR SCHEMA RELEASE NOT SUPPORTED
Explanation: Strobe for CA Gen did not identify a CA Gen, AllFusion Gen, Advantage Gen, or COOL:Gen generated module containing action diagram statements, or Strobe for CA Gen does not support the release of CA Gen, AllFusion Gen, Advantage Gen, or COOL:Gen that generated the application modules. Schema refers to an internal number that identifies the release level of the software.
System Action: Strobe continues sampling but does not create reports for CA Gen.
User Response: To determine the Schema Release Level number, see the SUBSYSTEM field on the Measurement Session Data report. If this field identifies a release level that Strobe for CA Gen supports, measure a program that is experiencing more activity. If this field does not reflect a schema number, then Strobe for CA Gen could not determine the release level.
If there is no schema number, review the Strobe Program Usage Summary report and the Program Usage by Procedure report to see which modules Strobe identified.
Contact Compuware Customer Support to resolve the problem.