Network Connections
The following figure is a diagram that shows all the connections needed for ISPW to integrate with BMC Compuware Enterprise Services (CES) and Topaz Workbench, depending on the versions you are running for each.
Network Connections for ISPW Integration
Configuration Example Diagrams
The following figures provide a template to follow for identifying all the parameters that must be updated and the ports that must be kept in sync to support
ISPW
on the mainframe,
Topaz Workbench
, HCI/CMSC, and
CES
.
Parameters and Ports
The following table lists the related parameters and ports.
Single LPAR Parameters and Ports
CM Parameters | CI Parameters | CT Parameters | CMSC Ports | HCI Ports |
---|---|---|---|---|
SERVERID | SERVERID | SERVERID | CES_HOST | HCI_HOST |
WZCMNAME | WZCMNAME | WZCMNAME | CES_PORT | HCI_PORT |
WZCINAME | WZCINAME | WZCTNAME | ISPW_HOST | |
WZCTNAME | WZCMPORT | XSYSPROT | ISPW_PORT | |
XSYSPROT | XSYSPROT | WZCMADDR | ||
WZCMADDR | WZCMADDR | WZCMPORT - PORT | ||
WZCIADDR | XMEMID | WZCTADDR | ||
WZCMPORT - PORT | WZCIPORT - PORT | TCPUSERID | ||
WZCMXPRT - PORT | WZCIXPRT - PORT | |||
TCPUSERID | WZCIADDR | |||
*WEBAPI=Y | ||||
*CUSTOMDIALOGS | ||||
*CONFIGNAMES |
Configuration Considerations
- The minimum releases for each product are ISPW 18.02, Topaz Workbench 18.03, CES 18.03, and ECC 17.02 (for HCI and CMSC).
- All ports are listening ports.
- For the parameter CUSTOM_DIALOGS, specify Y (Yes) if you want to enable the use of custom generate dialogs. The default is N (No).
- For the parameter CONFIG_NAMES, specify Y (Yes) to enable loading a list of valid runtime configuration names for this CM. See Define CM Specific Parameters in Milestone 8: Define Started Tasks for more information. The default is N (No).
- The ISPW_PORT must match the WZCMXPRT.
- Host Connection settings are used to specify port connection to the HCI. There must be at least one HCI port configured per LPAR.
- You must specify the HCI_PORT as a Topaz user or in CES. This should be entered under Host Connections for the Port field.
Single LPAR
The following figure illustrates a single LPAR.
Simple Single LPAR ISPW Configuration
The following figure illustrates a simple single ISPW LPAR configuration.
Topaz Workbench for ISPW Configuration
The following figure illustrates Topaz Workbench for ISPW Configuration.
CES REST API/Webhooks for ISPW Configuration
The diagram in the following figure uses the same CM and HCI as those shown in the Topaz Workbench for ISPW Configuration diagram.
CES
REST API/Webhooks for
ISPW
Configuration
Adding a CT and/or CI for a Remote LPAR
On the M.SV screen, add entry:
- Server Name - ISPWCT
- System Type - MVS
- Server Type - CT
- Address - IP address of ISPW CT
- Socket - Port for file transfers from other CT/RMT SRVR/Topaz 18.2
- CSS Socket - Port for Topaz 18.2+
- Deploy - Y/N
- Description - Default MVS CT SERVER
Adding a CT and/or CI for a Remote LPAR