Passing BMP parameters to IMS
BMP_IN
Description: BMP IN. Max. length 8.
Specify the input transaction code.
Default: blank
BMP_OUT
Description: BMP OUT. Max. length 8.
Specify the output transaction code.
Default: blank
BMP_OPT
Description: BMP OPT. Max. length 1.
Valid entries are N (ask operator), W (Wait), or C (Cancel).
Specify which option to enable when the IMSID or ALTID system is not available.
Default: N
BMP_SPIE
Description: BMP SPIE. Max. length 1.
Valid entries are 0 (No) or 1 (Yes).
Specify whether to allow SPIE established by the application program.
Default: 0
BMP_TEST
Description: BMP TEST. Max. length 1.
Valid entries are 0 (do not validate) or 1 (validate).
Specify whether to validate addresses in the call list.
Default: 0
BMP_DIRCA
Description: BMP DIRCA. Max. length 3.
Specify the dependent region inter-region communication area size.
Default: 000
BMP_PRLD
Description: BMP PRLD. Max. length 2.
Specify whether to pre-load the list suffix, DFSMPLxx.
Default: blank
BMP_STIMER
Description: BMP STIMER. Max. length 1.
Valid entries are 0 (No) or 1 (Yes).
Specify whether to gather processor time statistics.
Default: blank
BMP_CKPTID
Description: BMP CKPTID. Max. length 8.
Specify the checkpoint for the restart of the program.
Default: blank
BMP_PARDLI
Description: BMP PARDLI. Max. length 1.
Valid entries are 0 (enabled) or 1 (disabled).
Specify whether the parallel DL/I option is enabled.
Default: 1
BMP_CPUTIME
Description: BMP CPUTIME. Max. length 4.
Valid entries are 0 (none) or 1 through 1440 (maximum time in minutes).
Specify the task timing option.
Default: blank
BMP_NBA
Description: BMP NBA. Max. length 4.
Specify the initial number of fast path buffers for DEDB.
Default: 5
BMP_OBA
Description: BMP OBA. Max. length 4.
Specify the overflow number of fast path buffers for DEDB.
Default: 5
BMP_IMSID
Description: BMP IMSID. Max. length 4.
Specify the IMS subsystem ID.
Default: ID01
Required: yes
BMP_AGN
Description: BMP AGN. Max. length 8.
Specify the application group name.
Default: blank
BMP_SSM
Description: BMP SSM. Max. length 4.
Specify the subsystem member suffix for external subsystems.
Default: blank
BMP_PREINIT
Description: BMP PREINIT. Max. length 2.
Specify the pre-initialization list suffix, DFSINTxx.
Default: blank
BMP_ALTID
Description: BMP ALTID. Max. length 4.
Specify the alternate IMS system.
Default: blank
BMP_LOCKMAX
Description: BMP LOCKMAX. Max. length 5.
Valid entries are 0 (none) or 1 through 32,767.
Specify the locking limit, which overrides PSB LOCKMAX. This value locks in units of 1,000.
Default: blank