Milestone 13: Load Initial Reference Data


In this milestone, you will load the initial metadata required for the SITE Application, which is used to customize Code Pipeline for your installation.

If you are performing an upgrade (and keeping the existing SITE data sets), skip ahead to Milestone-14-Configure-Workbench-for-Eclipse-Integration.

Important

Roles involved: Code Pipeline Installer

Task 13.1 Navigate to the Reference Data update menu

  1. To load the initial data, go to the Code Pipeline Main Menu and enter option M.R. The screen shown in the following figure will be displayed showing the initial data as implemented in the install jobs. If this is not shown, the Db2 Repository Install has not completed successfully.Reference Data Maintenance screen

    M.R               REFERENCE DATA MAINTENANCE (PROD)               BROWSE MODE  
    Command  ===>                                                 Scroll ===> CSR  
                                                                                  
    List Commands: L Locate Entry, U Update Mode                                   
    Line Commands: S Select, V View                                                
                                                                                  
                                                                                  
      Code Key1     Key2     Key3     Vers Version Description  Actv Loaded RefrReq
       __  ________ ________ ________ ____ ____________________   _     _      _   
    __ AA                             0000 INSTALL VERSION        Y     Y          
    __ AD  PLAY     PLAY     PLAY     0000 INSTALL VERSION        Y     Y          
    __ AD  SITE     SITE     SITE     0000 INSTALL VERSION        Y     Y          
    __ AG                             0000 INSTALL VERSION        Y     Y          
    __ AP                             0000 INSTALL VERSION        Y     Y          
    __ AR                             0000 INSTALL VERSION        Y     Y          
    __ BC                             0000 INSTALL VERSION        Y     Y          
    __ CC                             0000 INSTALL VERSION        Y     Y          
    __ CT                             0000 INSTALL VERSION        Y     Y          
    __ DC                             0000 INSTALL VERSION        Y                
    __ DD                             0000 INSTALL VERSION        Y                
    __ DS                             0000 INSTALL VERSION        Y                
    __ DT                             0000 INSTALL VERSION        Y                
    __ DV                             0000 INSTALL VERSION        Y                
    __ EC                    WRMPARM  0000 INSTALL VERSION        Y     Y          
    __ EC                    WRSPARM  0000 INSTALL VERSION        Y     Y          
    __ EC                    WRSSCHED 0000 INSTALL VERSION        Y     Y          
    __ EC                    WRSVRCTL 0000 INSTALL VERSION        Y     Y          
    __ EC                    WZGPARMS 0000 INSTALL VERSION        Y     Y          
    __ EC                    WZGWORK  0000 INSTALL VERSION        Y     Y          
    __ ER                             0000 INSTALL VERSION        Y     Y          
    __ EX                             0000 INSTALL VERSION        Y     Y          
    __ ST                    PLAY     0000 INSTALL VERSION        Y     Y          
    __ ST                    SITE     0000 INSTALL VERSION        Y     Y          
    ******************************* Bottom of data ********************************
  2. Enter “Update” mode by typing U on the Command line and pressing Enter. The options at the top of the screen will change to include all the Update Operations, as shown in the following figure.

    Reference Data Maintenance screen - Update mode

    M.R               REFERENCE DATA MAINTENANCE (PROD)               UPDATE MODE  
    Command  ===>                                                 Scroll ===> CSR  
                                                                                  
    List Commands: A Add, L Locate Entry, B Browse Mode                            
    Line Commands: S Select, D Delete, C Clone, I Import, E Export                 
                   V View, M Modify, A Activate                                    
                                                                                  
      Code Key1     Key2     Key3     Vers Version Description  Actv Loaded RefrReq
       __  ________ ________ ________ ____ ____________________   _     _      _   
    __ AA                             0000 INSTALL VERSION        Y     Y          
    __ AD  PLAY     PLAY     PLAY     0000 INSTALL VERSION        Y     Y

Task 13.2 Import sample component type data

Sample Data needs to be loaded for Reference Codes CT, BC, CC, ST, ER, EX, EC, and AD.

  1. Type an I (Import) next to CT and press Enter. The screen in the following figure will be displayed, except the Version Description and Import Dataset Name will not be filled in yet.Import CT Reference Data screen

    M.R               IMPORT CT REFERENCE DATA (PROD)                            
    Command  ===>                                                 Scroll ===> CSR
                                                                                
     Define details for the requested Component Type Table Import                
                                                                                
     Version Description ==> Import from Samplib                                 
     Import Dataset Name ==> ISPW.MPWM220.BPWMSAMP(REF#CT)                       
                                                                                
                                                                                
     Press ENTER to continue with the import request or END to terminate.        

  2. Type the Version Description as shown above.
  3. Type your BPWMSAMP library name with member REF#CT, as shown above.
  4. Press Enter. After the import has successfully been completed, the screen shown in the following figure is displayed.Reference Data Maintenance screen - CT import complete



    M.R               REFERENCE DATA MAINTENANCE (PROD)               UPDATE MODE  
    Command  ===>                                                 Scroll ===> CSR  
                                                                                  
    List Commands: A Add, L Locate Entry, B Browse Mode                            
    Line Commands: S Select, D Delete, C Clone, I Import, E Export                 
                   V View, M Modify, A Activate                                                                                                                   
                                                                                  
      Code Key1     Key2     Key3     Vers Version Description  Actv Loaded RefrReq
       __  ________ ________ ________ ____ ____________________   _     _      _   
    __ AA                             0000 INSTALL VERSION        Y     Y          
    __ AD  PLAY     PLAY     PLAY     0000 INSTALL VERSION        Y     Y          
    __ AD  SITE     SITE     SITE     0000 INSTALL VERSION        Y     Y          
    __ AG                             0000 INSTALL VERSION        Y     Y          
    __ AP                             0000 INSTALL VERSION        Y     Y          
    __ AR                             0000 INSTALL VERSION        Y     Y          
    __ BC                             0000 INSTALL VERSION        Y     Y          
    __ CC                             0000 INSTALL VERSION        Y     Y          
    __ CT                             0001 Import from Samplib                     
    __ CT                             0000 INSTALL VERSION        Y     Y          
    __ DC                             0000 INSTALL VERSION        Y                
    __ DD                             0000 INSTALL VERSION        Y                
    __ DS                             0000 INSTALL VERSION        Y                
    __ DT                             0000 INSTALL VERSION        Y                
    __ DV                             0000 INSTALL VERSION        Y                
    __ EC                    WRMPARM  0000 INSTALL VERSION        Y     Y          
    __ EC                    WRSPARM  0000 INSTALL VERSION        Y     Y          
    __ EC                    WRSSCHED 0000 INSTALL VERSION        Y     Y          
    __ EC                    WRSVRCTL 0000 INSTALL VERSION        Y     Y          
    __ EC                    WZGPARMS 0000 INSTALL VERSION        Y     Y          
    __ EC                    WZGWORK  0000 INSTALL VERSION        Y     Y          
    __ ER                             0000 INSTALL VERSION        Y     Y          
    __ EX                             0000 INSTALL VERSION        Y     Y          
    __ ST                    PLAY     0000 INSTALL VERSION        Y     Y          
    __ ST                    SITE     0000 INSTALL VERSION        Y     Y          
    ******************************* Bottom of data ********************************

  5. Repeat Step 1 through Step 4 above for each of the members listed in the following table, by typing an I next to the respective code and pressing Enter. Make sure the PDS member is correct for each one, as listed in the following table. After the imports, the screen shown in Reference Data Maintenance Screen - All Imports Complete is displayed.

Initial reference data

Reference Data

Samplib Member

Description

Component Types

REF#CT

Basic set of component type definitions (e.g. Assembler, COBOL, etc.)

Base Component Types

REF#BC

Basic set of supported cross reference types

Component Categories

REF#CC

Basic set of Component Categories for the Cross Reference

SITE Stream Definition

REF#ST

Defines a Stream within which Applications are Defined

External Reference Data

REF#ER

A standard set of data required for normal Code Pipeline Processing

Exits

REF#EX

A set of standard Code Pipeline Exits which are required for normal Code Pipeline Processing.

Extension Class WZGPARMS

REF#PARM

Generate Parms

Extension Class WZGWORK

REF#WORK

Generate Parms (Working copy for HOLD Compile)

Site Application

REF#AD

Definitions for the Code Pipeline Application which will be used to manage the Code Pipeline customizations for your installation. This data will have been tailored for the Site standards as part of the Edit Macro steps.

Important

PLAY#ST and PLAY#AD will be addressed in IVP #2.

Reference Data Maintenance screen - All imports complete

M.R               REFERENCE DATA MAINTENANCE (PROD)               UPDATE MODE  
Command  ===>                                                 Scroll ===> CSR  
                                                                              
List Commands: A Add, L Locate Entry, B Browse Mode                            
Line Commands: S Select, D Delete, C Clone, I Import, E Export                 
               V View, M Modify, A Activate                                    
                                                                              
  Code Key1     Key2     Key3     Vers Version Description  Actv Loaded RefrReq
   __  ________ ________ ________ ____ ____________________   _     _          
__ AA                             0000 INSTALL VERSION        Y     Y          
__ AD  PLAY     PLAY     PLAY     0000 INSTALL VERSION        Y     Y          
__ AD  SITE     SITE     SITE     0001 Import from Samplib                     
__ AD  SITE     SITE     SITE     0000 INSTALL VERSION        Y     Y          
__ AG                             0000 INSTALL VERSION        Y     Y          
__ AP                             0000 INSTALL VERSION        Y     Y          
__ AR                             0000 INSTALL VERSION        Y     Y          
__ BC                             0001 Import from Samplib                     
__ BC                             0000 INSTALL VERSION        Y     Y          
__ CC                             0001 Import from Samplib                     
__ CC                             0000 INSTALL VERSION        Y     Y          
__ CT                             0001 Import from Samplib                     
__ CT                             0000 INSTALL VERSION        Y     Y          
__ DC                             0000 INSTALL VERSION        Y                
__ DD                             0000 INSTALL VERSION        Y                
__ DS                             0000 INSTALL VERSION        Y                
__ DT                             0000 INSTALL VERSION        Y                
__ DV                             0000 INSTALL VERSION        Y                
__ EC                    WRMPARM  0000 INSTALL VERSION        Y     Y          
__ EC                    WRSPARM  0000 INSTALL VERSION        Y     Y          
__ EC                    WRSSCHED 0000 INSTALL VERSION        Y     Y          
__ EC                    WRSVRCTL 0000 INSTALL VERSION        Y     Y          
__ EC                    WZGPARMS 0001 Import from Samplib                     
__ EC                    WZGPARMS 0000 INSTALL VERSION        Y     Y          
__ EC                    WZGWORK  0001 Import from Samplib                     
__ EC                    WZGWORK  0000 INSTALL VERSION        Y     Y          
__ ER                             0001 Import from Samplib                     
__ ER                             0000 INSTALL VERSION        Y     Y          
__ EX                             0001 Import from Samplib                     
__ EX                             0000 INSTALL VERSION        Y     Y          
__ ST                    PLAY     0000 INSTALL VERSION        Y     Y          
__ ST                    SITE     0001 Import from Samplib                     
__ ST                    SITE     0000 INSTALL VERSION        Y     Y          
******************************* Bottom of data ********************************

Task 13.3 Activate the newly loaded data

Each of the newly loaded reference data types needs to be activated. This indicates to Code Pipeline that this data is to become the currently used data. The order in which they are activated is important because the data is referentially validated. Activate them as follows:

  1. Type an A (Activate) next to each version just loaded, in the following order:
    1. CC
    2. BC
    3. CT
    4. ST
    5. AD
    6. EX
    7. ER
    8. EC WZGPARMS
    9. EC WZGWORK

After they have been activated, the screen will be displayed as shown in the following figure.

Reference Data Maintenance screen - All activations complete

M.R               REFERENCE DATA MAINTENANCE (PROD)   Activated - Refresh Reqd
Command  ===>                                                 Scroll ===> CSR  
                                                                              
List Commands: A Add, L Locate Entry, B Browse Mode                            
Line Commands: S Select, D Delete, C Clone, I Import, E Export                 
               V View, M Modify, A Activate                                    
                                                                              
  Code Key1     Key2     Key3     Vers Version Description  Actv Loaded RefrReq
   __  ________ ________ ________ ____ ____________________   _     _      _   
__ AA                             0000 INSTALL VERSION        Y     Y          
__ AD  PLAY     PLAY     PLAY     0000 INSTALL VERSION        Y     Y          
__ AD  SITE     SITE     SITE     0001 Import from Samplib    Y            Y   
__ AD  SITE     SITE     SITE     0000 INSTALL VERSION              Y          
__ AG                             0000 INSTALL VERSION        Y     Y          
__ AP                             0000 INSTALL VERSION        Y     Y          
__ AR                             0000 INSTALL VERSION        Y     Y          
__ BC                             0001 Import from Samplib    Y            Y   
__ BC                             0000 INSTALL VERSION              Y          
__ CC                             0001 Import from Samplib    Y            Y   
__ CC                             0000 INSTALL VERSION              Y          
__ CT                             0001 Import from Samplib    Y            Y   
__ CT                             0000 INSTALL VERSION              Y          
__ DC                             0000 INSTALL VERSION        Y                
__ DD                             0000 INSTALL VERSION        Y                
__ DS                             0000 INSTALL VERSION        Y                
__ DT                             0000 INSTALL VERSION        Y                
__ DV                             0000 INSTALL VERSION        Y                
__ EC                    WRMPARM  0000 INSTALL VERSION        Y     Y          
__ EC                    WRSPARM  0000 INSTALL VERSION        Y     Y          
__ EC                    WRSSCHED 0000 INSTALL VERSION        Y     Y          
__ EC                    WRSVRCTL 0000 INSTALL VERSION        Y     Y          
__ EC                    WZGPARMS 0001 Import from Samplib    Y            Y   
__ EC                    WZGPARMS 0000 INSTALL VERSION              Y          
__ EC                    WZGWORK  0001 Import from Samplib    Y            Y   
__ EC                    WZGWORK  0000 INSTALL VERSION              Y          
__ ER                             0001 Import from Samplib    Y            Y   
__ ER                             0000 INSTALL VERSION              Y          
__ EX                             0001 Import from Samplib    Y            Y   
__ EX                             0000 INSTALL VERSION              Y          
__ ST                    PLAY     0000 INSTALL VERSION        Y     Y          
__ ST                    SITE     0001 Import from Samplib    Y            Y   
__ ST                    SITE     0000 INSTALL VERSION              Y          
******************************* Bottom of data ********************************

Task 13.4 Refresh the server

The Code Pipeline Server now needs to be “refreshed”. This will cause the Server to load the active data into its cache. Refresh the Server as follows:

  1. Enter =M.SM on the Code Pipeline Command line. The Server Control screen is displayed.Server Control Refresh screen

    M.SM ------------ SERVER PROD CONTROL (PROD) ----------------------------------
    COMMAND ===>                                                                   
                                                                                  
                                                                                  
      The following commands can be disruptive to users and should be used with   
      care.                                                                       
                                                                                  
             R   REFRESH       - Refresh reference/control data                   
             P   STOP          - Stop request processing                          
             S   START         - Start request processing                         
             D   DLGREFR       - Refresh Custom Dialog data                       
             C   CFGREFR       - Refresh Config Name Table                        
                                                                                  
      The following commands should only be performed under the direction of      
      Technical Support staff.                                                    
                                                                                  
             T   TRACE START   - Start ALL Server Tracing                         
             X   TRACE STOP    - Stop ALL Server Tracing                          
             M   TRACE MODIFY  - Modify Server Trace operation                    
                                                                                  
       If 'M', New Trace Control Statement                                        
       ==>                                                                        
                       END to return to previous menu.                            
  2. Type R (REFRESH) in the COMMAND field and press Enter to refresh the server with the loaded Reference Data.
Warning

Exit and re-enter 

Code Pipeline

 before proceeding to refresh your local cache.

 

Tip: For faster searching, add an asterisk to the end of your partial query. Example: cert*