Activating IMS Connect RTN/RSN codes
To display the IMS Connect generic reason codes, activate the option to replace the Energizer reason codes with the corresponding IMS Connect reason codes. With generic reason codes, your existing automation (that you created by using reason codes from IMS Connect) continues to work.
Activating the option to replace Energizer reason codes with IMS Connect reason codes does not replace Energizer-specific reason codes. IMS Connect reason codes replace Energizer-specific reason codes only if both codes have the same descriptions.
To activate the option
- Navigate to the IMS Connect Options panel.
Type a forward slash (/) before the Activate IBM IMS Connect RSM RTN/RSN Codes option and save the options.
IPRPOCN0 IMS Connect Options
More: +
Type Connect options. Scroll down for more options.
Started task name. . . ________ +
Description . . . . . __________________________________________
Group name . . . . . . ________ +(Use Prompt for list)
Router options name . ________ +
Exit options name . . ________ +
ODBM options name . . ________ +
Execute cmds member . ________ (in PROCLIB)
Auto cancel clients . ________ (in PROCLIB)
Host name . . . . . . __________________________________________
Port number . . . . . _____ (1 to 65535) _ Enable exclusive port
Exit Security Options
Security class name. . ________
Security application . ________
Resource prefix . . . ________________________________________
Transport Layer Security (TLS/AT-TLS) Options
/ Propagate UserID associated with Digital Certificate
_ Validate UserID in IRM/OTMA headers vs Certificate UserID
_ Cache Certificate associated UserID
_ All Ports 1. 19233 2. 3. 4. 5.
Governor Options
Transaction limit . . 0_________ (transactions per second)
Warning threshold . . 0_ (0 to 99 percent of transaction limit)
Cycle interval . . . . 5_ (5-60 seconds)
Low warning limit . . 0_______ (transactions per second)
Select (type a '/') any of the following.
_ Cache security resource profiles
/ Activate tracing for types selected below
/ Activate journaling for types selected below
_ Pass IMS Connect data to Logger
_ Activate IBM IMS Connect RSM RTN/RSN Codes
Command ===> ______________________________________________________Reload the IMS Connect option by using the RELOAD command.
For more information, see Reloading-IMS-Connect-configurations.
To deactivate the option
- Navigate to the IMS Connect Options panel.
- In the Activate IBM IMS Connect RSM RTN/RSN Codes option, delete the forward slash (/) and save the options.
- Reload the IMS Connect options by using the RELOAD command.