Setting trace options in the IMS Connect address space
To set IMS Connect trace options
- Select 1. Configure Energizer from the Energizer ISPF interface Primary Menu.
- Select IMS connect options member to edit.
- Enable Activate tracing for types selected.
Select or deselect the Trace types to be collected.
IMS Connect Options
More: - +
Select which trace and journal types are to be collected.
Reset all trace and journal selections below to default values
Type Trace Journal
ACTL - address space control . / /
CMDS - commands . . . . . . . . / /
COMP - components . . . . . . . / /
ERRS - errors . . . . . . . . . / /
HIST - history . . . . . . . . / /
SECS - security . . . . . . . . / /
STAT - statistics . . . . . . . / /
TRAN - transactions . . . . . . / /
XCFC - XCF control . . . . . . / /
EVNT - events . . . . . . . . . / /
DISP - dispatcher . . . . . . . / /
JRNL - journal . . . . . . . . /
LTCH - latches . . . . . . . . / /
STRG - storage . . . . . . . . / /
Command ===>For information about the field definitions in the IMS Connect address space, see Using-trace-and-journal-options or press F1 for online Help.
- Press PF3 to save.
- (Optional) Reload the option. For information on reloading IMS Connect options, see Reloading-IMS-Connect-configurations.
Tip: For faster searching, add an asterisk to the end of your partial query. Example: cert*