Invoking the Energizer ISPF interface


When you start Energizer, the Energizer logo panel is displayed.

To invoke the 

Energizer

 ISPF interface to perform an action:

  1. Invoke the Energizer ISPF interface step 1 from the Energizer logo panel, and press Enter.
    The following figure shows the BMC AMI Energizer for IMS Connect - Primary Menu panel:

     File  Display  Help                                                           
    ------------------------------------------------------------------------------
                       BMC AMI Energizer for IMS Connect - Primary Menu            
                                                                        More:     +
    Select one of the following.  Then press Enter.                                
                                                                                  
    _ 1. Configure Energizer                                                       
            Options library __________________________________                     
            Options module  ________ (Blank or pattern for selection list)         
                                                                                  
       2. Query IMS Connect                                                        
       3. Issue Commands                                                           
       4. Verify IMS Connectivity (test transactions)                              
          Choose an IMS Connect for options 2,3, or 4                              
            IMS Connect . . ________ + (Blank or pattern for selection list)       
            TCP/IP Host . . ________________________________________
            TCP/IP Port . . _____
                                                                                  
       5. Set BMC Software Product Authorization by CPU ID   
            Product Code. . _____

    '+' following an entry field indicates that the PROMPT action is available.
  2. Perform an action from the BMC AMI Energizer for IMS Connect - Primary Menu, type the number for the action, and press Enter.The following table lists the available actions on the BMC AMI Energizer for IMS Connect - Primary Menu and describes what each action does:

    Action

    Description

    Reference

    Configure Energizer

    Configure the Energizer Options Library and members, by adding, updating, reloading, and deleting eLinks, eGroups, IMS Connects, IMS Systems, exits, and routing


    Query IMS Connects

    Get transaction trace information, historical statistical information (hourly and by routing cycle)

    Issue Commands

    Display, reload, set, and reset options and exits and IMS Connect z/OS and OM Type-2 commands

    Verify IMS Connectivity (test transactions)

    Verify connectivity by sending transactions and IMS commands to the specified IMS Connect

    Set BMC Software Product Authorization by CPU ID

    Set BMC Software product authorization by CPU ID

    Enter a valid product code provided to you by BMC. For example, IPR, IPT, MIS, or CSU

    Tip

    The following information on the BMC AMI Energizer for IMS Connect - Primary Menu applies to Querying Active IMS Connects, Energizer commands, and Verifying IMS Connectivity:

            IMS Connect . . ________                                           
            TCP/IP Host . . ________________________________________           
            TCP/IP Port . . _____

    If you do not enter an IMS Connect name when you select option 2, 3, or 4, the IMS Connect List panel IMS Connect List panel is displayed. Before you can continue, you must select which IMS Connect configuration member to use. The list is constructed when Energizer reads the options library and tries to contact each IMS Connect. If you specify a host and port on the BMC AMI Energizer for IMS Connect - Primary Menu, that IMS Connect is contacted also.

    The following figure shows a sample IMS Connect List panel:

                                 IMS Connect List               Row 1 to 5 of 5
                                                          Commands: Locate SORT
    The following IMS Connects were discovered.  Select one.  Then press Enter.
      S=Select for this query only   U=Use as default for all queries          
    A Name     Time Started      IPR Ver. Port  Host or -Error message         
    _ CONN2    -- N/A --                  _____ -Port not specified in options
    _ TXCIC212 -- Active --               12345 -TCP/IP Socket1 connected      
    _ TXCIC22I -- N/A --                  _____ -Port not specified in options
    _ TXCIC222 -- Inactive --             11052 -TCP/IP Socket1 connect failed
    _ TXCIC91  -- Inactive --             11504 -TCP/IP Socket1 connect failed

 

Tip: For faster searching, add an asterisk to the end of your partial query. Example: cert*