Invoking the Energizer ISPF interface
To invoke the
Energizer
ISPF interface to perform an action:
Invoke the Energizer ISPF interface step 1 from the Energizer logo panel, and press Enter.
The following figure shows the BMC AMI Energizer for IMS Connect - Primary Menu panel:File Display Help
------------------------------------------------------------------------------
BMC AMI Energizer for IMS Connect - Primary Menu
More: +
Select one of the following. Then press Enter.
_ 1. Configure Energizer
Options library __________________________________
Options module ________ (Blank or pattern for selection list)
2. Query IMS Connect
3. Issue Commands
4. Verify IMS Connectivity (test transactions)
Choose an IMS Connect for options 2,3, or 4
IMS Connect . . ________ + (Blank or pattern for selection list)
TCP/IP Host . . ________________________________________
TCP/IP Port . . _____
5. Set BMC Software Product Authorization by CPU ID
Product Code. . _____
'+' following an entry field indicates that the PROMPT action is available.Perform an action from the BMC AMI Energizer for IMS Connect - Primary Menu, type the number for the action, and press Enter.The following table lists the available actions on the BMC AMI Energizer for IMS Connect - Primary Menu and describes what each action does:
Action
Description
Reference
Configure Energizer
Configure the Energizer Options Library and members, by adding, updating, reloading, and deleting eLinks, eGroups, IMS Connects, IMS Systems, exits, and routing
Query IMS Connects
Get transaction trace information, historical statistical information (hourly and by routing cycle)
Issue Commands
Display, reload, set, and reset options and exits and IMS Connect z/OS and OM Type-2 commands
Verify IMS Connectivity (test transactions)
Verify connectivity by sending transactions and IMS commands to the specified IMS Connect
Set BMC Software Product Authorization by CPU ID
Set BMC Software product authorization by CPU ID
Enter a valid product code provided to you by BMC. For example, IPR, IPT, MIS, or CSU
With the IMS Connect List panel you can use the selected IMS Connect for this query only or use it as the default for all queries. The options library should contain a member for the selected IMS Connect. If no configuration member is found, default values are used.
The following figure shows a sample IMS Connect List panel:
IMS Connect List Row 1 to 5 of 5
Commands: Locate SORT
The following IMS Connects were discovered. Select one. Then press Enter.
S=Select for this query only U=Use as default for all queries
A Name Time Started IPR Ver. Port Host or -Error message
_ CONN2 -- N/A -- _____ -Port not specified in options
_ TXCIC212 -- Active -- 12345 -TCP/IP Socket1 connected
_ TXCIC22I -- N/A -- _____ -Port not specified in options
_ TXCIC222 -- Inactive -- 11052 -TCP/IP Socket1 connect failed
_ TXCIC91 -- Inactive -- 11504 -TCP/IP Socket1 connect failed