Server commands supported by the BMC AMI Datastream for IMS server


You can issue commands from the operator console to the BMC AMI Datastream for IMS server by either issuing a modify command (F server_task_name, command) or by replying to the BMCAFI000001I WTOR message (nnnnCommand) . For example,
F BMCAFI,OPTS
or
0405OPTS

The BMC AMI Datastream for IMS server supports the following server commands:

Category

Command

Description

Actions

OPTS

Reloads the server options in the BMC AMI Datastream for IMS server

When the /server command is executed:

  • The extracted fields are flushed to the output destinations. If a destination is a Generation Data Group (GDG) data set, the current generation is closed and a new one is opened.
  • TCP/IP connections are closed and opened again.
  • The input sources (IMS, IMS Connect, and so on) are disconnected and re-connected to the server.

RELUEXIT   

Reloads the user exit routine AFIUEXIT

SHUTDOWN

Shuts down the BMC AMI Datastream for IMS server after closing data sets and disconnecting from sources and destinations.

CONN imsid

Connects the server to the indicated IMS

DISC imsid

Disconnects the server from the indicated IMS

PAU imsid

Pauses the data collection for the indicated IMS

RES imsid

Resumes the data collection for the indicated IMS or all IMSs

RELO imsid

Reloads the IMSID options for the indicated IMS

DBFILTER (imsid | ALL)

Reloads the Database Filter options for the indicated IMS or ALL IMSs

DBSTOP imsid

Stops logging DL/I database access in the indicated IMS

Statistics

LIST

Lists all the IMS subsystems connected to this server   

STATS

Displays statistics for BMC AMI Datastream for IMS

RESET imsid

Resets performance statistics for the indicated IMS

PERFORM imsid

Displays performance statistics for the indicated IMS

Diagnostics

ABEND

Abend is taken for BMC AMI Datastream for IMS server

DUMP

Creates an SVC DUMP for the BMC AMI Datastream for IMS server

HELP

Displays the command list and descriptions

 

Tip: For faster searching, add an asterisk to the end of your partial query. Example: cert*