Displaying detailed information for a PPRC device


The PPRC device subpanel displays detailed information about a single PPRC object. To access this information, type 1 (Zoom) next to the desired device on the PPRC objects panel and press Enter.

PPRC Device subpanel

                 PPRC device on 03/19/2012 at 10:00:41                  
                                                                          
 Address  . . : 15312         Status . . : Offline
 Device type  : 3390-C        Cyls/Blks  :   10017
 Volser . . . :               Voluse . . :         
 CU type  . . : 2107          CUSSid . . : 5300    

     
                                                                          
                        Primary    Secondary                              
  SSid . . . . . . :       0023         0127                               
  CUSNum . . . . . :      40118        40118                               
  CCA  . . . . . . :         EE           EE                               
  LSS  . . . . . . :         00           00                               
                                                                         
  State  . . . . . : DUPLEX                  First cyl pend :     0       
  Level  . . . . . : PRIMARY                 Last cyl pend  :     0       
  Critical . . . . : No                      Copy . . . . . :     0 %     
                                                                          
   F1=Help     F4=Print    F5=Mirrors   F6=Paths  F12=Cancel

The following table explains describes the detailed information about a PPRC device that is available on this subpanel.

Detailed information for a PPRC device

Field

Description

Address

The address of the device

(SPE2110) A five digit device address can be displayed

Status

The current status of the device—online or offline

Device Type

The type of device

Cyls/Blks

The total number of cylinders or blocks (depending on device)

Volser

The volume serial number of this device

Voluse

The volume usage description for this device

CU type

The device type of the control unit

CUSSid

The subsystem ID of the control unit

SSid - Primary

The subsystem ID of the control unit for the current (or last connected) primary volume in a duplex pair

CUSNum - Primary

The serial number of the control unit for the current (or last connected) primary volume in a duplex pair

CCA - Primary

The channel connection address of the current (or last connected) primary volume in a duplex pair

LSS - Primary

The logical subsystem number of the primary volume in a duplex pair

SSid - Secondary

The subsystem ID of the control unit for the current (or last connected) secondary volume in a duplex pair.

CUSNum - Secondary

The serial number of the control unit for the current (or last connected) secondary volume in a duplex pair.

CCA - Secondary

The channel connection address of the current (or last connected) secondary volume in a duplex pair

LSS - Secondary

The logical subsystem of the current secondary volume in a duplex pair

State

The PPRC state of the device

  • SUSPEND indicates that writes to the secondary volume have been suspended.
  • PENDING indicates that a copy is in progress.
  • DUPLEX indicates that the primary and secondary volumes are synchronized.
  • SIMPLEX indicates that the PPRC state before pairing or pairs have been terminated.
  • A blank value indicates the PPRC state was not determined during device discovery.

First cyl pend

The lowest cylinder that is out of synchronization

Level

The PPRC level for this device

  • PRIMARY indicates that this volume is the source volume in a mirrored (duplex) pair.
  • SECONDARY indicates that this volume is the target volume in a mirrored (duplex) pair.
  • A blank value indicates a volume that has not been mirrored.

Last cyl pend

The highest cylinder that is out of synchronization

Critical

The value of the CRIT parameter as specified on the CESTPAIR command

Copy

The percent complete for a copy operation

This value is displayed only on a primary volume.

 

Tip: For faster searching, add an asterisk to the end of your partial query. Example: cert*