Displaying detailed information for a PPRC device
PPRC Device subpanel
Address . . : 15312 Status . . : Offline
Device type : 3390-C Cyls/Blks : 10017
Volser . . . : Voluse . . :
CU type . . : 2107 CUSSid . . : 5300
Primary Secondary
SSid . . . . . . : 0023 0127
CUSNum . . . . . : 40118 40118
CCA . . . . . . : EE EE
LSS . . . . . . : 00 00
State . . . . . : DUPLEX First cyl pend : 0
Level . . . . . : PRIMARY Last cyl pend : 0
Critical . . . . : No Copy . . . . . : 0 %
F1=Help F4=Print F5=Mirrors F6=Paths F12=Cancel
The following table explains describes the detailed information about a PPRC device that is available on this subpanel.
Detailed information for a PPRC device
Field | Description |
---|---|
Address | The address of the device (SPE2110) A five digit device address can be displayed |
Status | The current status of the device—online or offline |
Device Type | The type of device |
Cyls/Blks | The total number of cylinders or blocks (depending on device) |
Volser | The volume serial number of this device |
Voluse | The volume usage description for this device |
CU type | The device type of the control unit |
CUSSid | The subsystem ID of the control unit |
SSid - Primary | The subsystem ID of the control unit for the current (or last connected) primary volume in a duplex pair |
CUSNum - Primary | The serial number of the control unit for the current (or last connected) primary volume in a duplex pair |
CCA - Primary | The channel connection address of the current (or last connected) primary volume in a duplex pair |
LSS - Primary | The logical subsystem number of the primary volume in a duplex pair |
SSid - Secondary | The subsystem ID of the control unit for the current (or last connected) secondary volume in a duplex pair. |
CUSNum - Secondary | The serial number of the control unit for the current (or last connected) secondary volume in a duplex pair. |
CCA - Secondary | The channel connection address of the current (or last connected) secondary volume in a duplex pair |
LSS - Secondary | The logical subsystem of the current secondary volume in a duplex pair |
State | The PPRC state of the device
|
First cyl pend | The lowest cylinder that is out of synchronization |
Level | The PPRC level for this device
|
Last cyl pend | The highest cylinder that is out of synchronization |
Critical | The value of the CRIT parameter as specified on the CESTPAIR command |
Copy | The percent complete for a copy operation This value is displayed only on a primary volume. |