Revalidating mirrored object sets
Before you generate disaster recovery JCL, you should revalidate object sets in batch mode either through the online interface or by running the ARMBGPV batch revalidation program.
The online method is described in the following sections. For more information about using ARMBGPV, see the BMC AMI Recovery Manager for Db2 documentation.
The revalidation procedure automatically verifies the mirroring status of the system resources and reports mirroring exceptions when it revalidates a object set. System resources are revalidated once per revalidation job, regardless of how many object sets are being revalidated. Before generating disaster recovery JCL, you should revalidate mirrored object sets to check the recoverability of objects and to verify mirroring status.
To revalidate mirrored object sets
- From the main menu, select Option 1, Application object sets to display the Object set List panel.
- Enter an object set name or wildcard pattern to display a list of object sets to revalidate.
Type R next to a single object set (or RA to report on all displayed object sets).The Batch Object Set Report Options panel is displayed.
ARMVO001 == Batch Object Set Report Options ==========
Command ===> _________________________________________________________________
Type information below. Then press Enter.
Report type . . . . . . . 1 1. Revalidation 2. Impact analysis
Site type . . . . . . . 1 1. Local 2. Recovery
JCL type. . . . . . . . 1 1. Local 2. DR
Recovery Resources. . . 1 1. Yes 2. No
Recoverability. . . . . 1 1. Yes 2. No
Tape pick list. . . . . 1 1. Yes 2. No
Data set recall list. . 1 1. Yes 2. No
Archive copy. . . . . . _ 1. Archive 1 2. Archive 2 3. Offsite Log
Mirror System . . . . . 2 1. Yes 2. NoOn the Batch Object Set Report Options panel, set the following values and press Enter:
Option
Value
Report type
1. Revalidation
JCL Type
2. DR
The second Batch Object Set Report Options panel is displayed.
ARMVO002 == Batch Object Set Report Options - (2 OF 2) ==========
Command ===> _________________________________________________________________
Type information below. Then press Enter.
Recover to. . . . . . . 1 1. Current 2. Image copy 3. Quiesce
4. Restart RBA/LRSN 5. Specific Logpoint
6. Timestamp 7. Logmark
Full copy only. . . . . 2 1. Yes 2. No (for option 2)
Relative point. . . . 0_ 0=Last to 99=99th previous (for options 2, 3, or 7)
To Timestamp . . . ____ - __ - __ __ : __ : __ : __ (Inflights resolved)
To Logpoint . . . . . . ____________
Resolve Inflights . 1. Yes 2. No
To Logmark . . . . . . ____________
Backout . . . . . . . . 3 1. Yes 2. No 3. Auto (for RECOVER PLUS only)
Report clones only. . . 2 1. Yes 2. NoOn the second Batch Object Set Report Options panel, set the following values:
Option
Value
Recover to
4. Restart RBA/LRSN
Backout
2. No
On the JCL specification panel, type a data set name and press Enter to generate the revalidation job and submit the job.Mirroring exceptions for subsystem resources are written to the ARMXCEPT file. If mirroring exceptions are found for application data sets, information messages are written to ARMPRINT.
Related topic