Information
Limited support BMC provides limited support for this version of the product. As a result, BMC no longer accepts comments in this space. If you encounter problems with the product version or the space, contact BMC Support.BMC recommends upgrading to the latest version of the product. To see documentation for that version, see Recovery Management for Db2 13.1.

Activating mirroring support for system resources


The Recovery Management solution defines five levels of mirroring support for system resources.

At a minimum, you must mirror both the BSDS and active logs (Level 1). The mirroring levels are as follows:

Mirroring level

BSDS and active logs

Catalog and directory

Rmgr repository

Log Master repository

Level 1

Yes

No

No

No

Level 2

Yes

Yes

No

No

Level 3

Yes

Yes

Yes

No

Level 4

Yes

Yes

No

Yes

Level 5

Yes

Yes

Yes

Yes

 You activate remote mirroring support for system resources by defining your remote mirroring strategy in one of the following ways:


 