Space announcement This space provides the same content as before, but the organization of the home page has changed. The content is now organized based on logical branches instead of legacy book titles. We hope that the new structure will help you quickly find the content that you need.

Troubleshooting SmartSwitch


If SmartSwitch fails when attempting to switch a job from REORG PLUS to BMC AMI Reorg, resubmit the original REORG PLUS JCL with the REORG PLUS restart parameter:

  • If BMC AMI Reorg can run the failed job, SmartSwitch automatically translates the restart parameter specified in REORG PLUS's PARM= clause to be BMC AMI Utilities compatible, as follows:

    REORG PLUS parameter

    BMC AMI Reorg parameter

    Null

    RESTART

    NEW

    NORESTART

    RESTART

    RESTART

    NEW/RESTART

    RESTART

    NEW/RESTART(PHASE)

    RESTART

    TERM

    QUICKEXIT

  • If BMC AMI Reorg cannot run the failed job, REORG PLUS runs the job. 

 

Tip: For faster searching, add an asterisk to the end of your partial query. Example: cert*