Limited supportBMC provides limited support for this version of the product. As a result, BMC no longer accepts comments in this space. If you encounter problems with the product version or the space, contact BMC Support.BMC recommends upgrading to the latest version of the product. To see documentation for that version, see REORG PLUS for DB2 13.1.

Using the SIXSNAP option


The SIXSNAP option determines whether REORG PLUS uses the Instant Snapshot technology of 

XBM

 and 

SUF

 to create a copy of storage-group-defined nonpartitioned indexes.

To use Instant Snapshot, you must have a supported intelligent storage device. For a list of supported devices, see the EXTENDED BUFFER MANAGER for DB2 documentation.

The following table shows how the value of the SIXSNAP command or installation option determines the action that REORG PLUS takes if a copy failure occurs.

SIXSNAP value

Instant Snapshot fails for

REORG PLUS action

AUTO

One or more nonpartitioned indexes

Makes a software-based copy of each index that failed

One or more components of a multi-data-set object

Makes a software-based copy of every component of that multi-data-set index

YES

Any index

Terminates

We recommend that you specify AUTO instead of YES, especially if your hardware vendor is STK. For more information, see Hardware vendor considerations.

For information about the XBM and SUF requirements, see XBM-and-SUF-considerations.

To use Instant Snapshot technology to copy nonpartitioned indexes

  1. Ensure that you have a currently supported version of XBM or SUF as described in System-requirements.
  2. Ensure that you have a supported intelligent storage device (as documented in the EXTENDED BUFFER MANAGER for DB2 documentation).
  3. Specify AUTO or YES on the SIXSNAP command or installation option.
  4. Specify YES on the REDEFINE command or installation option.If the value for REDEFINE is NO, REORG PLUS operates as follows:
    • If SIXSNAP is AUTO, REORG PLUS changes SIXSNAP to NO and produces a software-based copy.
    • If SIXSNAP is YES, REORG PLUS terminates.
  5. (optional) Use the XBMID installation or command option to specify the XBM subsystem that you want REORG PLUS to use for snapshot processing.
  6. Review the information in the rest of this section for any additional actions to take.

 