SYNCVAL—Synchronize Db2 statistics
Use the Modify Synchronize Statistics Recording panel or the SYNCVAL command to specify whether Db2 statistics recording is synchronized with some part of the hour. Synchronization can occur at the beginning of the hour or at any number of minutes past the hour, up to 59.
Modify Synchronize Statistics Recording panel
Command ===> _________________________________________________________________
Command: CURRENT
Description . . . . . . . . : SYNCHRONIZE DB2 STATISTICS
Type the new Synchronize Statistics Recording value you wish to change to. Then press Enter.
Synchronize Statistics Recording Indicator
Sync Stat Indicator . . . . (N, 0 - 59 or delta)
Command syntax and parameters

Value | Description |
|---|---|
DB2ssid | Db2 subsystem ID or the name of the Db2 data sharing group to which the command applies. |
opertuneID | OPERTUNE system profile name (if OPERTUNE is running as a started task) or the batch job name (if OPERTUNE is running as a batch job). |
N | No synchronization takes place. This is the Db2 default. |
0 | Statistics recording is synchronized to the beginning of the hour. |
value | Statistics recording is synchronized to the specified number of minutes past the hour. |
NORESET | The changes you request remain in effect until the Db2 subsystem is cycled. |
Db2 parameter values
Field | Installation panel | CLIST parameter | ZPARM macro | ZPARM parameter |
|---|---|---|---|---|
Sync Stat Indicator | DSNTIPN | SYNCVAL | DSN6SYSP | SYNCVAL |