Limited supportBMC provides limited support for this version of the product. As a result, BMC no longer accepts comments in this space. If you encounter problems with the product version or the space, contact BMC Support.BMC recommends upgrading to the latest version of the product. To see documentation for that version, see High-speed Apply Engine 13.1.

UNIT parameter


For z/OS, the UNIT parameter specifies a storage unit type that the High-speed Apply Engine uses to allocate temporary files for apply processing.

  

Attributes

This parameter has the following attributes:

 

Attribute

Value

Section

[TemporaryFiles]

Abbreviation

None

DBMS

Db2

Required?

No

Valid values

Any valid storage unit identifier for your environment, except VIO

Default value

SYSALLDA

  

Usage

If you specified a value for the STORCLAS parameter, you do not need to specify a unit type. If your environment uses DFSMS, High-speed Apply Engine specifies the UNIT parameter in its allocation request, but the operating system does not honor its value.


 