Maintaining the BMCDICT table
If LOADPLUS or REORG PLUS abends during the time between building the compression dictionary and completing compression, rows might remain in the BMCDICT table. If you need to control the expansion of this table, use the following procedure:
- Delete any rows in the BMCUTIL table that you know are no longer valid.
Do not delete any rows for instances of utilities that are awaiting restart. Use the SQL statement to delete rows from the BMCDICT table:
DELETE
FROM creatorName.CMN_BMCDICT
WHERE UTILID NOT IN
(SELECT UTILID FROM creatorName.CMN_BMCUTIL);
Related topics