XSUTXTND (data set space extension) automation control point


Use the XSUTXTND automation control point to provide the volume serial number for additional data set space.

The product invokes this automation control point when a data set needs to extend to a new volume.

Variables

The following table describes the variables used in the XSUTXTND automation control point:


Variable name

Contents

Possible values

Notes

dsname

Name of the DB2 object data set name

You cannot change this value.

A value in the following form:

VCATName.DSNDBD.databaseName.spaceName.I0001.Annn


stortype

Indicates how the data set is managed

You cannot change this value.

  • I (DB2 storage-group managed)
  • E (user managed)


volume

Volume serial number

You can change this value.

Blank (default) or volume serial number

If the data set is SMS -managed, you can use the following statement:

volume = '*'

Return codes

The XSUTXTND automation control point returns the following return codes:

Return code

Description

0

(default value) Signifies normal completion

No action is required.

Any other value

Abnormal termination

Set the return code to any non-zero value to cancel the entire job.


 

Tip: For faster searching, add an asterisk to the end of your partial query. Example: cert*