NGTDISP report
The NGTDISP report contains information about products that are currently running or started. For information about producing this report, see NGTDISP-command.
Following is the sample report
UTILITY-ID STATUS TYPE STARTED ENDED JOBNAME JOB # STEPNAME CODE AGE
---------------- ------------ -------- ------------------- ------------------- -------- -------- -------- ---- ---
RGLOD12 NO RESTART LOAD 2019-07-19 12:30:17 2019-07-19 12:31:54 RGLOD12 J0566685 PS010 8 5
RGLOD12 COMPLETED OK LOAD 2019-07-19 12:31:54 2019-07-19 12:32:37 RGLOD12 J0566744 PS010 4 5
RGULD121 COMPLETED OK UNLOAD 2019-07-19 12:33:20 2019-07-19 12:33:43 RGULD121 J0566781 UNLOAD 0 5
RGRRG12 COMPLETED OK REORG 2019-07-19 12:34:23 2019-07-19 12:36:24 RGRRG12 J0566811 PS010 0 5
RGRRG12 COMPLETED OK REORG 2019-07-19 12:37:36 2019-07-19 12:38:32 RGRRG12 J0566898 PS010 0 5
RGCPY12 COMPLETED OK COPY 2019-07-19 12:38:49 2019-07-19 12:39:17 RGCPY12 J0566931 PS010 0 5
RGSTT12 COMPLETED OK RUNSTATS 2019-07-19 12:39:51 2019-07-19 12:39:58 RGSTT12 J0566963 PS010 4 5
RGSTT12 COMPLETED OK RUNSTATS 2019-07-19 12:40:33 2019-07-19 12:41:06 RGSTT12 J0566979 PS010 0 5
RGMIX12 COMPLETED OK MIXED 2019-07-19 12:41:22 2019-07-19 12:41:51 RGMIX12 J0566995 UNLOAD 0 5
RGDSP12 COMPLETED OK NGTDISP 2019-07-19 13:15:59 2019-07-19 13:16:11 RGDSP12 J0567813 PS010 0 5
RGSTT12 COMPLETED OK RUNSTATS 2019-07-19 13:17:12 2019-07-19 13:17:33 RGSTT12 J0567839 PS010 0 5
RGCPY12 COMPLETED OK COPY 2019-07-19 13:18:03 2019-07-19 13:18:22 RGCPY12 J0567852 PS010 0 5
RGCPY12 COMPLETED OK COPY 2019-07-19 13:19:02 2019-07-19 13:19:21 RGCPY12 J0567866 PS010 0 5
RGRRG12 COMPLETED OK REORG 2019-07-19 13:20:42 2019-07-19 13:21:29 RGRRG12 J0567885 PS010 0 5
RGDSP12 COMPLETED OK NGTDISP 2019-07-19 13:22:43 2019-07-19 13:22:55 RGDSP12 J0567904 PS010 0 5
RGDSP12 COMPLETED OK NGTDISP 2019-07-19 13:26:48 2019-07-19 13:27:01 RGDSP12 J0567940 PS010 0 5
RGULD121 COMPLETED OK UNLOAD 2019-07-19 13:59:23 2019-07-19 13:59:45 RGULD121 J0568332 UNLOAD 0 5
RGDSP12 COMPLETED OK NGTDISP 2019-07-19 14:08:39 2019-07-19 14:08:50 RGDSP12 J0568500 PS010 0 5
RGDSP12 JOB RUNNING NGTDISP 2019-07-19 14:14:04 RGDSP12 J0568541 PS010 5
The SS column has a Y value if the utility was executed by SmartSwitch:
UTILITY-ID STATUS TYPE STARTED ENDED JOBNAME JOB # STEPNAME CODE AGE S U
---------------- ------------ -------- ------------------- ------------------- -------- -------- -------- ---- --- - -
*Q1884382 COMPLETED OK CHECKIX 2021-05-02 07:39:42 2021-05-02 07:39:47 SCCIUB01 J0231063 NGTCHK 0 5
F436823C RESTARTABLE LOAD 2020-04-20 03:05:27 F436823C J0710775 NGTLOAD0 255 5
*RGDSP12 COMPLETED OK NGTDISP 2020-07-10 09:06:30 2020-07-10 09:06:34 RGDSP12 J0422801 PS010 0 5
Q1884382 COMPLETED OK UNLOAD 2021-05-02 07:39:36 2021-05-02 07:39:40 SCCIUB01 J0231063 BMCUNLD1 0 5 Y
AMUCLN01 RESTARTABLE UNLOAD 2019-07-01 14:18:29 SMARTSW J0432887 BMCLOAD1 255 5 Y
KNRULD1B RESTARTABLE UNLOAD 2020-05-18 09:50:04 KNRULD1B J0993224 UNLOAD 255 5
The DU column has a Y value if the utility has a duration value:
UTILITY-ID STATUS TYPE STARTED ENDED JOBNAME JOB # STEPNAME CODE AGE S U
---------------- ------------ -------- ------------------- ------------------- -------- -------- -------- ---- --- - -
*RGRRG12 COMPLETED OK MIXED 2021-05-06 11:54:35 2021-05-06 12:26:00 RGRRG12 J0299193 REORG 0 5 Y
*RGDSP12 NO RESTART NGTDISP 2021-05-05 14:14:38 2021-05-05 14:27:38 RGDSP12 J0290368 DISPLAY 8 5
RGDSP12 JOB RUNNING NGTDISP 2021-05-06 12:35:59 RGDSP12 J0299455 DISPLAY 5
Following is a sample report when using the QUALIFIER|QUAL keyword (PTF BQU2620 applied)
UTILITY-ID STATUS TYPE STARTED ENDED JOBNAME JOB # STEPNAME CODE AGE
---------------- ------------ -------- ------------------- ------------------- -------- -------- -------- ---- ---
RGLOD12 NO RESTART LOAD 2019-07-19 12:30:17 2019-07-19 12:31:54 RGLOD12 J0566685 PS010 8 5
DATASET QUALIFIER=NGHBMFND.FBMAHDJA
RGLOD12 COMPLETED OK LOAD 2019-07-19 12:31:54 2019-07-19 12:32:37 RGLOD12 J0566744 PS010 4 5
DATASET QUALIFIER=NGHBMGDA.AFHMOHIG
RGULD121 COMPLETED OK UNLOAD 2019-07-19 12:33:20 2019-07-19 12:33:43 RGULD121 J0566781 UNLOAD 0 5
DATASET QUALIFIER=NGHBMGIB.OAKIIJJG
RGRRG12 COMPLETED OK REORG 2019-07-19 12:34:23 2019-07-19 12:36:24 RGRRG12 J0566811 PS010 0 5
DATASET QUALIFIER=NGHBMGLN.LOIHFNJG
RGRRG12 COMPLETED OK REORG 2019-07-19 12:37:36 2019-07-19 12:38:32 RGRRG12 J0566898 PS010 0 5
DATASET QUALIFIER=NGHBMHHF.FKNDDBJC
RGCPY12 COMPLETED OK COPY 2019-07-19 12:38:49 2019-07-19 12:39:17 RGCPY12 J0566931 PS010 0 5
DATASET QUALIFIER=NGHBMHLL.MBILADJF
RGSTT12 COMPLETED OK RUNSTATS 2019-07-19 12:39:51 2019-07-19 12:39:58 RGSTT12 J0566963 PS010 4 5
DATASET QUALIFIER=NGHBMHPG.NLJELPKA
RGSTT12 COMPLETED OK RUNSTATS 2019-07-19 12:40:33 2019-07-19 12:41:06 RGSTT12 J0566979 PS010 0 5
DATASET QUALIFIER=NGHBMIBO.HHJBMBJG
RGMIX12 COMPLETED OK MIXED 2019-07-19 12:41:22 2019-07-19 12:41:51 RGMIX12 J0566995 UNLOAD 0 5
DATASET QUALIFIER=NGHBMIEN.IIMLLJJD
RGDSP12 COMPLETED OK NGTDISP 2019-07-19 13:15:59 2019-07-19 13:16:11 RGDSP12 J0567813 PS010 0 5
DATASET QUALIFIER=NGHBNAAK.EJEHJBIB
RGSTT12 COMPLETED OK RUNSTATS 2019-07-19 13:17:12 2019-07-19 13:17:33 RGSTT12 J0567839 PS010 0 5
DATASET QUALIFIER=NGHBNAEP.IMHMNNJC
RGCPY12 COMPLETED OK COPY 2019-07-19 13:18:03 2019-07-19 13:18:22 RGCPY12 J0567852 PS010 0 5
DATASET QUALIFIER=NGHBNAIA.DGBCALJF
RGCPY12 COMPLETED OK COPY 2019-07-19 13:19:02 2019-07-19 13:19:21 RGCPY12 J0567866 PS010 0 5
DATASET QUALIFIER=NGHBNALI.JNMONLJC
RGRRG12 COMPLETED OK REORG 2019-07-19 13:20:42 2019-07-19 13:21:29 RGRRG12 J0567885 PS010 0 5
DATASET QUALIFIER=NGHBNBBI.EKHPHPJD
RGDSP12 COMPLETED OK NGTDISP 2019-07-19 13:22:43 2019-07-19 13:22:55 RGDSP12 J0567904 PS010 0 5
DATASET QUALIFIER=NGHBNBIL.NAOIFPJG
RGDSP12 COMPLETED OK NGTDISP 2019-07-19 13:26:48 2019-07-19 13:27:01 RGDSP12 J0567940 PS010 0 5
DATASET QUALIFIER=NGHBNCHF.BFCFKFID
RGULD121 COMPLETED OK UNLOAD 2019-07-19 13:59:23 2019-07-19 13:59:45 RGULD121 J0568332 UNLOAD 0 5
DATASET QUALIFIER=NGHBNJLN.MOHGAJIC
RGDSP12 COMPLETED OK NGTDISP 2019-07-19 14:08:39 2019-07-19 14:08:50 RGDSP12 J0568500 PS010 0 5
DATASET QUALIFIER=NGHBNLMP.IHBKEJJD
RGDSP12 JOB RUNNING NGTDISP 2019-07-19 14:14:04 RGDSP12 J0568541 PS010 5
DATASET QUALIFIER=NGHBNNAF.GBEDADIB
The following table describes the column definitions:
UTILITY-ID | Specifies the utility ID | ||||||||||||||||||
UTILITY STATUS | The status of the associated utility ID
| ||||||||||||||||||
UTILITY TYPE | (PTF BQU2620 applied) The type of utility that is currently running or being started. The possible utility types are; CHECKIX, COPY, LOAD, MIXED, NGTDISP, REBUILD, REORG, RUNSTATS, UNLOAD. | ||||||||||||||||||
STARTED | The date and time at which the product was started | ||||||||||||||||||
ENDED | The date and time at which the product ended, if completed. If the product is still active, this field will not have a value. Products with an abend (RC=255) will not have an end time. | ||||||||||||||||||
JOBNAME | The name of the job associated with the utility ID | ||||||||||||||||||
JOB # | The job number associated with the utility ID | ||||||||||||||||||
STEPNAME | The step name associated with the utility ID | ||||||||||||||||||
RET CODE | The highest return code for the job step. The return code for abends is 255. | ||||||||||||||||||
DATASET QUALIFIER | Unique qualifier used for the BMC AMI Utilities VSAM work data sets | ||||||||||||||||||
SS | (BMC.DB2.SPE2110) The SS column has a Y value if the utility was executed by SmartSwitch. | ||||||||||||||||||
DU | (BMC.DB2.SPE2110) The DU column has a Y value if the utility has a duration value. |
This sections contains the following topics:
Related topics