Information
Important We are integrating BMC AMI LOBMaster technology into the BMC AMI Reorg product and discontinuing BMC AMI LOBMaster as a separate product. For the latest integrated documentation, see BMC AMI Reorg for Db2 13.1.

+CHKRBA


This copy parameter applies to incremental copies only.

When +CHKRBA is set to INC or I and an incremental copy is requested, then CUMULATIVE NO is placed on the Copy statement that is sent to ACPMAIN.

Warning

Important

This parameter is only relevant to PGM=NGTUTIL jobs. This has been deprecated and replaced by PGM=ACPMAIN, now known as BMC AMI Copy. PGM=ACPMAIN does not use these parameters, it has keywords for this functionality.

CHKRBA (1).png

FULL or NO

(Default) Does not pass CUMULATIVE NO to ACPMAIN

INC or I

Pass CUMULATIVE NO to ACPMAIN

Information
Example

+CHKRBA(INC)

If BMC AMI Utilities determine an incremental copy is to be taken, pass CUMULATIVE NO to ACPMAIN

Warning

Important

For the rules that apply to parameter syntax, see Parameter syntax rules.

 

Tip: For faster searching, add an asterisk to the end of your partial query. Example: cert*

BMC AMI Reorg for Db2 13.1