Data sharing considerations
We recommend that you read the following information in the appropriate Db2 planning and administration guide:
- Discussions of the prerequisites for disaster recovery
- How to avoid using object set naming conventions that conflict with the coupling facility (XCF) object set names for disaster recovery
Permanently quiesced subsystems
It is possible for your data sharing system to have one or more permanently quiesced members that are no longer in use and do not need to be recovered even in the event of a system-wide disaster.
The ARMBSRR program allows you to enter the system IDs of such quiesced subsystems in order to exclude them from disaster recovery.
In the event that you need to start Db2 with a permanently quiesced member, you may receive the following error message:
DSNR020I csect-name START MEMBERmember, OR REPLY 'NO' OR 'QUIESCED'
Respond QUIESCED to tell Db2 that the member is quiesced.
A second message might appear:
DSNR030I csect-name WILL CONTINUE WITHOUT THE
member MEMBER'S LOG, REPLY 'YES' OR 'NO'
member MEMBER'S LOG, REPLY 'YES' OR 'NO'
Respond YES to continue without the quiesced member’s log.
Tip: For faster searching, add an asterisk to the end of your partial query. Example: cert*