MAXLOGS integer


The MAXLOGS option is part of the concurrent log file reading feature. Use this option to perform the following tasks:

  • Control the amount of memory that is used during the recovery
  • Reduce the contention that is caused by reading many log files in parallel

MAXLOGS must be greater than 0.

When MAXLOGS is specified, BMC AMI Recover will not allocate and read more log files concurrently than indicated by this option. If MAXLOGS is not coded on the OPTIONS command statement, the default is the value of the MAXLOGS installation option.

In addition to the global control that is provided by MAXDRIVES, use MAXLOGS to further control the number of tape drives that are used for the log files. If the value of MAXLOGS is less than MAXDRIVES, the number of tape drives that are used for log files is limited to the value of MAXLOGS.

 