Command log
The Command Log displays a list of commands that have been issued to Db2 as a result of recommendations from the system advisor.
To display the Command Log use the L action code against a Db2 subsystem.
PMDEQRPW/I BMC AMI Pool Advisor For Db2 Report Viewer LINE 1 OF 18
Command ====> _______________________________________________ Scroll ===> HALF
More: + >
BMCSftwr.PMDCMLOG -- COMMAND LOG -- 06/19 15:55:10
---< HELP >--------------------< *ALERT* >----------------------< CONFIG >---
Actions: ( + ) S - Details R - Response
DB2: DHY2 Rel: 9.1 DSGroup: DSNDHY DSMember: DHY2
Date-hour Command issued
-------------------------- ------------------------------------------------
+ 2008-06-19-15.55.09.895289 DB2 DHY2 -ALTER BUFFERPOOL(BP16K9) VPSIZE(497)
+ 2008-06-19-15.55.09.561965 DB2 DHY2 -ALTER BUFFERPOOL(BP16K0) VPSEQT(10)
+ 2008-06-19-15.55.09.374410 DB2 DHY2 -ALTER BUFFERPOOL(BP8K9) VPSIZE(573)
+ 2008-06-19-15.55.09.189666 DB2 DHY2 -ALTER BUFFERPOOL(BP8K0) VPSEQT(10)
+ 2008-06-19-15.55.09.041848 DB2 DHY2 -ALTER BUFFERPOOL(BP32K9) VPSIZE(125)
+ 2008-06-19-15.55.08.891025 DB2 DHY2 -ALTER BUFFERPOOL(BP32K) VPSIZE(312)
+ 2008-06-19-15.55.08.783964 DB2 DHY2 -ALTER BUFFERPOOL(BP49) VPSIZE(1698)
+ 2008-06-19-15.55.08.571915 DB2 DHY2 -ALTER BUFFERPOOL(BP2) VPSEQT(10)
+ 2008-06-19-15.55.08.363148 DB2 DHY2 -ALTER BUFFERPOOL(BP1) VPSEQT(10)
+ 2008-06-19-15.55.08.189011 DB2 DHY2 -ALTER BUFFERPOOL(BP0) VPSEQT(10)
+ 2008-06-19-15.52.37.712006 OPT DHY2 IN(DHY2) SET BP0(,,,10) NORESET
+ 2008-06-19-15.52.31.843789 OPT DHY2 IN(DHY2) SET BP1(,,,10) NORESET
+ 2008-06-19-14.26.32.311799 OPT DHY2 IN(DHY2) SET BP49(+49) NORESET
+ 2008-06-19-13.33.28.586190 OPT DHY2 IN(DHY2) SET BP35(+2750) NORESET
+ 2008-06-19-13.33.24.780377 OPT DHY2 IN(DHY2) SET BP34(+2750) NORESET
Command ====> _______________________________________________ Scroll ===> HALF
More: + >
BMCSftwr.PMDCMLOG -- COMMAND LOG -- 06/19 15:55:10
---< HELP >--------------------< *ALERT* >----------------------< CONFIG >---
Actions: ( + ) S - Details R - Response
DB2: DHY2 Rel: 9.1 DSGroup: DSNDHY DSMember: DHY2
Date-hour Command issued
-------------------------- ------------------------------------------------
+ 2008-06-19-15.55.09.895289 DB2 DHY2 -ALTER BUFFERPOOL(BP16K9) VPSIZE(497)
+ 2008-06-19-15.55.09.561965 DB2 DHY2 -ALTER BUFFERPOOL(BP16K0) VPSEQT(10)
+ 2008-06-19-15.55.09.374410 DB2 DHY2 -ALTER BUFFERPOOL(BP8K9) VPSIZE(573)
+ 2008-06-19-15.55.09.189666 DB2 DHY2 -ALTER BUFFERPOOL(BP8K0) VPSEQT(10)
+ 2008-06-19-15.55.09.041848 DB2 DHY2 -ALTER BUFFERPOOL(BP32K9) VPSIZE(125)
+ 2008-06-19-15.55.08.891025 DB2 DHY2 -ALTER BUFFERPOOL(BP32K) VPSIZE(312)
+ 2008-06-19-15.55.08.783964 DB2 DHY2 -ALTER BUFFERPOOL(BP49) VPSIZE(1698)
+ 2008-06-19-15.55.08.571915 DB2 DHY2 -ALTER BUFFERPOOL(BP2) VPSEQT(10)
+ 2008-06-19-15.55.08.363148 DB2 DHY2 -ALTER BUFFERPOOL(BP1) VPSEQT(10)
+ 2008-06-19-15.55.08.189011 DB2 DHY2 -ALTER BUFFERPOOL(BP0) VPSEQT(10)
+ 2008-06-19-15.52.37.712006 OPT DHY2 IN(DHY2) SET BP0(,,,10) NORESET
+ 2008-06-19-15.52.31.843789 OPT DHY2 IN(DHY2) SET BP1(,,,10) NORESET
+ 2008-06-19-14.26.32.311799 OPT DHY2 IN(DHY2) SET BP49(+49) NORESET
+ 2008-06-19-13.33.28.586190 OPT DHY2 IN(DHY2) SET BP35(+2750) NORESET
+ 2008-06-19-13.33.24.780377 OPT DHY2 IN(DHY2) SET BP34(+2750) NORESET
Use the S (Details) action code to expand the report to show details of the rule that triggered the recommendation. Use the R action code to see the command response. The following figure shows an example of the Command Log report expanded to show details and command responses for all commands.
PMDEQRPW/I BMC AMI Pool Advisor For Db2 Report Viewer LINE 1 OF 30
Command ====> _______________________________________________ Scroll ===> HALF
More: + >
BMCSftwr.PMDCMLOG -- COMMAND LOG -- 06/19 15:56:49
---< HELP >--------------------< *ALERT* >----------------------< CONFIG >---
Actions: ( + ) S - Details R - Response
DB2: DHY2 Rel: 9.1 DSGroup: DSNDHY DSMember: DHY2
Date-hour Command issued
-------------------------- ------------------------------------------------
+ 2008-06-19-15.55.09.895289 DB2 DHY2 -ALTER BUFFERPOOL(BP16K9) VPSIZE(497)
. Trigger rule: BR8 Change amount: 1152 Recommendation: DECREASE
Rule Description: Buffer pool size greater than MAX
----------------------------------------------------------------------------
+ 2008-06-19-15.55.09.561965 DB2 DHY2 -ALTER BUFFERPOOL(BP16K0) VPSEQT(10)
. Trigger rule: TS2 Change amount: 10 Recommendation: SET
Rule Description: VPSEQ threshold set too high
----------------------------------------------------------------------------
+ 2008-06-19-15.55.09.374410 DB2 DHY2 -ALTER BUFFERPOOL(BP8K9) VPSIZE(573)
. Return code: 0000
Response: DSNB522I *DHY2 VPSIZE FOR BP8K9 HAS BEEN SET TO 573 DSN9022 *DHY2 DSNB1CMD '-ALTER BUFFERPOO
---------------------------------------------------------------------------------------------------------------
+ 2008-06-19-15.55.09.189666 DB2 DHY2 -ALTER BUFFERPOOL(BP8K0) VPSEQT(10)
. Return code: 0000
Response: DSNB524I *DHY2 VPSEQT FOR BP8K0 HAS BEEN SET TO 10 DSN9022I*DHY2 DSNB1CMD '-ALTER BUFFERPOOL'
Command ====> _______________________________________________ Scroll ===> HALF
More: + >
BMCSftwr.PMDCMLOG -- COMMAND LOG -- 06/19 15:56:49
---< HELP >--------------------< *ALERT* >----------------------< CONFIG >---
Actions: ( + ) S - Details R - Response
DB2: DHY2 Rel: 9.1 DSGroup: DSNDHY DSMember: DHY2
Date-hour Command issued
-------------------------- ------------------------------------------------
+ 2008-06-19-15.55.09.895289 DB2 DHY2 -ALTER BUFFERPOOL(BP16K9) VPSIZE(497)
. Trigger rule: BR8 Change amount: 1152 Recommendation: DECREASE
Rule Description: Buffer pool size greater than MAX
----------------------------------------------------------------------------
+ 2008-06-19-15.55.09.561965 DB2 DHY2 -ALTER BUFFERPOOL(BP16K0) VPSEQT(10)
. Trigger rule: TS2 Change amount: 10 Recommendation: SET
Rule Description: VPSEQ threshold set too high
----------------------------------------------------------------------------
+ 2008-06-19-15.55.09.374410 DB2 DHY2 -ALTER BUFFERPOOL(BP8K9) VPSIZE(573)
. Return code: 0000
Response: DSNB522I *DHY2 VPSIZE FOR BP8K9 HAS BEEN SET TO 573 DSN9022 *DHY2 DSNB1CMD '-ALTER BUFFERPOO
---------------------------------------------------------------------------------------------------------------
+ 2008-06-19-15.55.09.189666 DB2 DHY2 -ALTER BUFFERPOOL(BP8K0) VPSEQT(10)
. Return code: 0000
Response: DSNB524I *DHY2 VPSEQT FOR BP8K0 HAS BEEN SET TO 10 DSN9022I*DHY2 DSNB1CMD '-ALTER BUFFERPOOL'
Related topic