Default language.

Information
Limited support BMC provides limited support for this version of the product. As a result, BMC no longer accepts comments in this space. If you encounter problems with the product version or the space, contact BMC Support.BMC recommends upgrading to the latest version of the product. To see documentation for that version, see BMC AMI Load for Db2 13.1.

XSUTSMSW (SmartSwitch) automation control point


Use the XSUTSMSW automation control point for the following tasks:

  • Prevent BMC AMI Utilities from processing the statement (force classic utilities)
  • Collect data on SmartSwitch utilities

XSUTSMSW invokes an automation control point each time a classic utility sends a statement to be verified (syntax checked) by BMC AMI Utilities.

Variables

The following table describes the variables used in the XSUTSMSW automation control point:

Variable name

Contents

Possible values

function_name 

Function name of the current utility statement 

OUTPUT

LOAD

REORG

UNLOAD

jobname

Name of the current job

JOBNAME

stepname

Name of the current job step

STEPNAME

statement

Text of the current statement

UTILITY STATEMENT

Return codes

The XSUTSMSW automation control point returns the following return codes:

Return code

Description

0

Allows BMC AMI Utilities to process the statement.

Any other value

Prevents BMC AMI Utilities from processing the statement.

 