Default language.

Limited supportBMC provides limited support for this version of the product. As a result, BMC no longer accepts comments in this space. If you encounter problems with the product version or the space, contact BMC Support.BMC recommends upgrading to the latest version of the product. To see documentation for that version, see BMC AMI Load for Db2 13.1.

+TIMEEXEC


The +TIMEEXEC parameter controls a second invocation of the XSUTTIME-SYSIN-based-job-termination-automation-control-point. If you define +TIMEEXEC YES,  

BMC AMI Utilities

 can make two time checks for deadline processing using the XSUTTIME automation control point .

GUID-4978EB21-AFCD-4F4E-AFE0-C31AA6F1CA5B-low.png

The values are defined as follows:

NO

(default) XSUTTIME is called once for each utility statement in the SYSIN.

YES

XSUTTTIME is called on two occasions:

  1. After processing each utility statement
  2. Before processing each object
Example
+TIMEEXEC(YES)

BMC AMI Utilities check the system time after processing the sysin statement, and again before processing each object in the statement. XSUTTIME can stop processing based on time of day or duration of the job.

Important

For the rules that apply to parameter syntax, see Parameter syntax rules.


 

Tip: For faster searching, add an asterisk to the end of your partial query. Example: cert*