Default language.

Writer instructions

Page title

For most spaces, this page must be titled Space announcements.

For spaces with localized content, this page must be titled Space announcements l10n.

Purpose

Provide an announcement banner on every page of your space.

Location

Move this page outside of your home branch.

Guidelines

Information
Limited support BMC provides limited support for this version of the product. As a result, BMC no longer accepts comments in this space. If you encounter problems with the product version or the space, contact BMC Support.BMC recommends upgrading to the latest version of the product. To see documentation for that version, see BMC AMI LOBMaster for Db2 13.1.

+UIDHISTORY


The +UIDHISTORY parameter specifies the number of days to retain utility ID (UID) history records in the BMC AMI Utilities checkpoint (CKPT) data set.

Warning

Important

You can set this parameter only during installation.

UIDHISTORY.png

 The value for numberOfDays can be from 0 to 180 days:

  • (SPE2010

    ) If you do not specify a number, the default value is 0.

  • If you specify 0
    • UID history records are not retained beyond the number of days specified in the OUTPUTAGE value.
    • (PTF BQU2620 applied) UID history records are deleted if +DELETEOUTPUT(YES)
      In this case, the product deletes the UID entry in the CKPT data set when the utility is completed.
Information
Example
+UIDHISTORY(30)

The product retains the UID history records for 30 days.

Information
Example
+UIDHISTORY(0)

Depending on the values specified for +OUTPUTAGE and +DELETEOUTPUT, the product:

  • Retains UID history records up to the value of +OUTPUTAGE
  • (PTF BQU2620 applied) Deletes the records immediately if +DELETEOUTPUT(YES)
Warning

Important

For the rules that apply to parameter syntax, see Parameter syntax rules.


 

Tip: For faster searching, add an asterisk to the end of your partial query. Example: cert*

BMC AMI LOBMaster for Db2