BMC AMI Application Restart Control abend codes
BMC AMI Application Restart Control (AR/CTL) products and their common routines produce abend codes when errors occur during the execution of an application program or a job step. This section lists and explains these abend codes in numerical sequence.
Number | Description | ||||||||
---|---|---|---|---|---|---|---|---|---|
SB22 | Explanation: The AR/CTL BCF component Cancel Intercept feature was scheduled and was not able to complete processing successfully. This abend was issued to simulate the original CANCEL request. Processing terminates abnormally. User response: Refer to message BMC48070I to determine why Cancel Intercept processing was not successful. | ||||||||
U061 or U1557 | Explanation: The BCF component of AR/CTL detected an incorrect use of the $BLPCALL macro. The job log data set may contain messages that provide additional information about this error. The abend code displayed depends on the value specified for the Use Abend Code Series (ABN) option. For more information, see the Use Abend Code Series option in Batch Control Facility. An AR/CTL BCF component or MVS system error has been encountered. User response: Ensure that a SYSUDUMP has been created and contact BMC Customer Support. | ||||||||
U063 or U1558 | Explanation: The BCF component of AR/CTL detected an error while processing the AR/CTL BCF component Physical Logger write queue. The write queue was empty after a BSAM write was issued. The abend code displayed depends on the value specified for the Use Abend Code Series option. For more information, see the Use Abend Code Series (ABN) option in the Batch Control Facility. The job step has abnormally terminated. This is an AR/CTL component Physical Logger internal error. User response: Ensure that a SYSUDUMP and the job log listings are available and contact BMC Customer Support. | ||||||||
U065 or U1559 | Explanation: The BCF component of AR/CTL detected an error while attempting to open the primary log data set. The primary log data set must be usable. The abend code displayed depends on the value specified for the Use Abend Code Series (ABN) option. For more information, see the Use Abend Code Series option in Batch Control Facility. This is a system error. User response: Verify that the specification of the primary log data set is correct. The job log data set may contain additional messages. If the Exchange Log Device Type option was specified as YES, verify that no error messages indicating allocation errors exist. If you need assistance, ensure that a SYSUDUMP is available and contact BMC Customer Support. | ||||||||
U066 or U1560 | Explanation: The AR/CTL BCF component Physical Logger action module was called, and the physical logging environment was not initialized. The abend code displayed depends on the value specified for the Use Abend Code Series (ABN) option. For more information, see the Use Abend Code Series option in Batch Control Facility. This is a system error. User response: Ensure that a SYSUDUMP and the job log listings are available and contact BMC Customer Support. | ||||||||
U067 or U1561 | Explanation: The AR/CTL BCF component Physical Logger action module was called with an invalid request type. The abend code displayed depends on the value specified for the Use Abend Code Series (ABN) option. For more information, see the Use Abend Code Series option in Batch Control Facility. This is a system error. User response: Ensure that a SYSUDUMP data set and the job log listings are available, and contact BMC Customer Support. | ||||||||
U071 or U1562 | Explanation: The AR/CTLBCF component Physical Logger received a bad return code from DBRC. U071 is the same abend that the standard IMS Physical Logger produces. The abend code displayed depends on the value specified for the Use Abend Code Series (ABN) option. For more information, see the Use Abend Code Series option in Batch Control Facility. This is a system error. User response: Refer to any DBRC messages for an indication of the nature of the DBRC problem. | ||||||||
U356 | Explanation: BMC AMI Application Restart Control for VSAM encountered an internal error before initialization of the modules that handle messages. The job step terminates abnormally. User response: Ensure that a SYSUDUMP and the job log listings are available, and contact BMC Customer Support. | ||||||||
U358 | Explanation: AR/CTL for VSAM encountered an unrecoverable error. The job step terminates abnormally. User response: Ensure that a SYSUDUMP and the job log listings are available, and contact BMC Customer Support. | ||||||||
U616 | Explanation: The BCF component of AR/CTL has determined that the log data set(s) have become unusable during logging. This is the same as the standard IMS abend U616. This is a system error. User response: Determine the reason for the log data set becoming unusable. If you cannot correct the problem, ensure that a SYSUDUMP and the job log listings are available and contact BMC Customer Support. | ||||||||
U617 or U1563 | Explanation: The BCF component of AR/CTL has determined that an invalid block count was requested for a buffered log device. The abend code displayed depends on the value specified for the Use Abend Code Series (ABN) option. For more information, see the Use Abend Code Series option in Batch Control Facility. This is a system error. User response: Ensure that a SYSUDUMP and the job log listings are available and contact BMC Customer Support. | ||||||||
U618 or U1564 | Explanation: The AR/CTL BCF component Physical Logger end-of-volume (EOV) routine was entered with an invalid address. The abend code displayed depends on the value specified for the Use Abend Code Series (ABN) option. For more information, see the Use Abend Code Series option in Batch Control Facility. This is a system error. User response: Ensure that a SYSUDUMP and the job log listings are available and contact BMC Customer Support. | ||||||||
U619 or U1565 | Explanation: The AR/CTL BCF component Physical Logger initialization detected an invalid IMS release level during initialization. The abend code displayed depends on the value specified for the Use Abend Code Series (ABN) option. For more information, see the Use Abend Code Series option in Batch Control Facility. This is a system or installation error. User response: Verify that the level of IMS being used is a supported level. If it is, ensure that a SYSUDUMP and the job log listings are available and contact BMC Customer Support. | ||||||||
U620 or U1566 | Explanation: The AR/CTL BCF component Physical Logger READ routine was unable to open any of the IMS log data sets for READ processing. The abend is produced so that the execution controller, if active, will attempt IMS batch backout. The abend code displayed depends on the value specified for the Use Abend Code Series (ABN) option. For more information, see the Use Abend Code Series option in Batch Control Facility. This is a system or installation error. User response: Determine why the open process failed. If you are unable to determine why this abend occurred, ensure that a SYSUDUMP data set, a job step dump, and the job log listings are available and contact BMC Customer Support. | ||||||||
U621 or U1567 | Explanation: The BCF component of AR/CTL has determined that the execution controller aborted processing because of an unrecoverable error. The abend code displayed depends on the value specified for the Use Abend Code Series option. For more information, see the Use Abend Code Series (ABN) option in Batch Control Facility. A resource necessary for step execution has become unavailable. User response: Review the job log for indications of the error condition, correct the error condition, and update the prior execution status to indicate the repair action that was taken. | ||||||||
U623 or U1569 | Explanation: The AR/CTL BCF component Physical Logger was not able to initialize. The Physical Logger Error option was specified as ABEND. The abend code displayed depends on the value specified for the Use Abend Code Series option. For more information, see the Use Abend Code Series (ABN) option in Batch Control Facility. This is an AR/CTL BCF component Physical Logger internal error. User response: Refer to messages in the job log for an indication of the problem. If you cannot determine the reason for the abend, ensure that a SYSUDUMP and the job log listings are available and contact BMC Customer Support. | ||||||||
U624 or U1570 | Explanation: The execution controller could not establish a restartable environment for the job step. The abend code displayed depends on the value specified for the Use Abend Code Series (ABN) option. For more information, see the Use Abend Code Series option in Batch Control Facility. The job log for this execution contains messages about the error(s) encountered. User response: Manual intervention is required. Correct the errors, update the REGISET to reflect changes that result from actions (log closure, backout, etc.) taken to correct the error(s), and restart the job step. | ||||||||
U625 or U1571 | Explanation: The execution controller has encountered an error that prevents further execution. The abend code displayed depends on the value specified for the Use Abend Code Series (ABN) option. For more information, see the Use Abend Code Series option in Batch Control Facility. The job log for this execution contains messages about the error(s) encountered. User response: Manual intervention is required. Correct the errors, update the REGISET to reflect changes that result from actions (log closure, backout, etc.) taken to correct the error(s), and restart the job step. | ||||||||
U626 or U1572 | Explanation: The AR/CTL BCF component Physical Logger has encountered an unrecoverable error during initialization. The abend code displayed depends on the value specified for the Use Abend Code Series (ABN) option. For more information, see the Use Abend Code Series option in Batch Control Facility. The initialization routine could not locate the directory module (BECDIR) containing the execution defaults. Control could not be returned to the IMS Physical Logger because module DFSXLGI0 could not be located. User response: Restart the job step, making certain that the modules necessary for execution are available. | ||||||||
U627 or U1573 | Explanation: The AR/CTLBCF component Physical Logger encountered an error while attempting to write critical restart information to the REGISET. This information is necessary to provide job step restart. The abend code displayed depends on the value specified for the Use Abend Code Series option. For more information, see the Use Abend Code Series (ABN) option in Batch Control Facility. Instead of risking a restart error, the job step terminates abnormally. User response: Correct the errors with the REGISET. If you are unable to do so, ensure that a SYSUDUMP and the job log listings are available and contact BMC Customer Support. | ||||||||
U628 or U1574 | Explanation: During batch backout, the BCF component of AR/CTL encountered COND=ONLY in a job step and backout completed successfully. Any subsequent job step that executes DFSBBO00 and contains COND=ONLY is bypassed. The abend code displayed depends on the value specified for the Use Abend Code Series option. For more information, see the Use Abend Code Series (ABN) option in Batch Control Facility. Processing continues. User response: This message is for your information only. No action is necessary. | ||||||||
U629 or U1577 | Explanation: During batch backout, the BCF component of AR/CTL encountered COND=ONLY in a job step but backout did not complete successfully. Any subsequent job step that executes DFSBBO00 and contains COND=ONLY is bypassed. The abend code displayed depends on the value specified for the Use Abend Code Series (ABN) option. For more information, see the Use Abend Code Series option in Batch Control Facility. Processing terminates. User response: Manual intervention is required. | ||||||||
U714 or U1575 | Explanation: The enhanced processing maintenance program detected an error that makes it impossible to complete the requested function. The abend code displayed depends on the value specified for the Use Abend Code Series (ABN) option. For more information, see the Use Abend Code Series option in Batch Control Facility. Processing terminates. User response: Refer to message BMC74421E for diagnostic information. If you are unable to resolve the problem, contact BMC Customer Support. | ||||||||
U747 | Explanation: The AR/CTL BCF component Backout Assist feature encountered an error that can make the results of the IMS Batch Backout utility execution unpredictable. The abend is issued to prevent database damage. The job step or the batch backout operation terminates abnormally. User response: If the reason for the abend cannot be determined and corrected, execute the IMS Batch Backout utility without the Backout Assist feature active. The Backout Assist feature can be deactivated by including a DD statement (BCFBAIGN, DD DUMMY) in the JCL for the step. | ||||||||
U778 | Explanation: AR/CTL detected that the application program issued a ROLL call. AR/CTL issues message BMC74297I and terminates abnormally. User response: Contact the application programmer to determine why the application issued the ROLL call and determine the action to take. | ||||||||
U1550 | Explanation: During AR/CTL BCF component restart processing, the previous job step abended, and the job step member was marked active. This user abend occurs when the last AR/CTL BCF component task that was active fails to complete its processing. Completion of job step processing is indicated by an “ENDED” or “ENDED+ABENDED” status message displayed beside the execution control record. Processing terminates. User response: Use the Display Active Job Step Member panel to mark the execution control record as abnormally terminated. As a result of this user abend, any steps coded as COND=ONLY for batch backout are bypassed if the AR/CTL BCF component is active for the job step. | ||||||||
U1551 | Explanation: An error occurred during AR/CTL processing. Processing terminates. User response: Check the messages issued during the job step for details about the cause of the error and the action to take. | ||||||||
U1552 | Explanation: AR/CTL BCF component restart processing has completed all recovery steps necessary for application restart. The execution control record indicates that deferred application restart processing has been requested. Processing terminates. User response: This abend is issued to prevent execution of any additional steps contained in the job and does not indicate an error condition. As a result of this user abend, any steps coded as COND=ONLY for batch backout are bypassed if the AR/CTL BCF component is active for the job step. | ||||||||
U1553 | Explanation: An error occurred during AR/CTL initialization. Processing terminates. User response: Check the messages issued during the job step for details about the cause of the error and the action to take. | ||||||||
U1554 | Explanation: The utility was not able to process the request successfully or encountered an error during processing. Processing terminates. User response: Correct the problem and resubmit the job. If the Automatic Restart Preparation utility produced this message, the BCFPRINT and/or ARCPRINT data sets contain additional information about the error. | ||||||||
U1555 | Explanation: The AR/CTL BCF component interface module was not able to find the BLPLCA control block. Processing terminates. User response: Contact BMC Customer Support for assistance. | ||||||||
U1556 | Explanation: The AR/CTL BCF component Cancel Intercept routines have transformed an operator CANCEL command into a user abend so that batch backout can be performed if necessary. Processing terminates. User response: Find out why the operator CANCEL was issued and resubmit the job. | ||||||||
U1557 | Explanation: See 'U061 or U1557'. User response: See 'U061 or U1557'. | ||||||||
U1558 | Explanation: See 'U063 or U1558'. User response: See 'U061 or U1557'. | ||||||||
U1559 | Explanation: See 'U065 or U1559'. User response: See 'U065 or U1559'. | ||||||||
U1560 | Explanation: See 'U066 or U1560'. User response: See 'U066 or U1560'. | ||||||||
U1561 | Explanation: See 'U067 or U1561'. User response: See 'U067 or U1561'. | ||||||||
U1562 | Explanation: See 'U071 or U1562'. User response: See 'U071 or U1562'. | ||||||||
U1563 | Explanation: See 'U617 or U1563'. User response: See 'U617 or U1563'. | ||||||||
U1564 | Explanation: See 'U618 or U1564'. User response: See 'U618 or U1564'. | ||||||||
U1565 | Explanation: See 'U619 or U1565'. User response: See 'U619 or U1565'. | ||||||||
U1566 | Explanation: See “U620 or U1566'. User response: See “U620 or U1566'. | ||||||||
U1567 | Explanation: See “U621 or U1567”. User response: “U621 or U1567”. | ||||||||
U1568 | Explanation: The execution controller detected that the program abended during execution. The job step has been recovered to a point ready for job step restart. The Program Abend option (set at the AR/CTL global level) was specified as BMC. User response: This abend does not indicate a problem with the BCF component of AR/CTL. This abend occurred so that, as the application program abended, it could be recognized by any automated operations products installed on the system. If you cannot determine the reason for the abend, ensure that a SYSUDUMP and the job log listings are available and contact BMC Customer Support. | ||||||||
U1569 | Explanation: See “U623 or U1569”. User response: See “U623 or U1569”. | ||||||||
U1570 | Explanation: See “U624 or U1570”. User response: See “U624 or U1570”. | ||||||||
U1571 | Explanation: See “U625 or U1571”. User response: See “U625 or U1571”. | ||||||||
U1572 | Explanation: See “U626 or U1572”. User response: See “U626 or U1572”. | ||||||||
U1573 | Explanation: See “U627 or U1573”. User response: See “U627 or U1573”. | ||||||||
U1574 | Explanation: See “U628 or U1574”. User response: See “U628 or U1574”. | ||||||||
U1575 | Explanation: See “U714 or U1575”. User response: See “U714 or U1575”. | ||||||||
U1576 | Explanation: The BMC application program interface controller was not able to correctly initialize the IMS application program interface. Processing terminates. User response: Contact BMC Customer Support, and have the job log data set available when you call. | ||||||||
U1577 | Explanation: See “U629 or U1577”. User response: See “U629 or U1577”. | ||||||||
U1578 | Explanation: An error occurred during AR/CTL for VSAM initialization or termination. Processing terminates. User response: Check the messages issued during the job step for details about the cause of the error and the action to take. | ||||||||
U1579 | Explanation: The RECOVERY PLUS for CICS/VSAM (RPCV) logger has encountered an unrecoverable error that prohibits continued logging. Processing terminates. User response: Restart the job step, making certain that the modules necessary for execution are available. | ||||||||
U1580 | Explanation: The BCF component of AR/CTL has detected an error. Processing terminates. User response: Check the AR/CTL BCF component messages issued during the job step for details about the cause of the error and the action to take. | ||||||||
U1770 | Explanation: The application sequential access method (ASAM) processor of AR/CTL has detected an internal logic error. AR/CTL issues message BMC74227I. Processing terminates. User response: Check the AR/CTL messages issued during the job step for details about the cause of the error and the action to take. | ||||||||
U1771 | Explanation: AR/CTL has detected an error or a user-requested abend. Processing terminates. User response: Check the AR/CTL messages issued during the job step for details about the cause of the error or user-requested abend and the action to take. | ||||||||
U1772 | Explanation: The application sequential access method (ASAM) processor of AR/CTL has detected an error during end-of-volume (EOV) processing. The EOV routine did not receive a valid file characteristics block (FCB) to process. Processing terminates. User response: Check the AR/CTL messages issued during the job step for details about the cause of the error and the action to take. | ||||||||
U1773 | Explanation: The application sequential access method (ASAM) processor of AR/CTL has detected an error during intercept processing. The intercept routine did not receive a valid data control block (DCB) to process. Processing terminates. User response: Check the AR/CTL messages issued during the job step for details about the cause of the error and the action to take. The following general registers contain more information about the abend: R4--The address of the DCB that was passed to the intercept routine. R15--The abend subcode that identifies the condition that the intercept routine found unacceptable:
| ||||||||
U1774 | Explanation: The application sequential access method (ASAM) processor of AR/CTL has detected that an ASAM staging area is full. In the file characteristics block (FCB) for the data set, the staging error option (STGERR) is set to ABEND. Processing terminates. User response: Check the AR/CTL messages issued during the job step for details about the cause of the error and the action to take. | ||||||||
U1775 | Explanation: The virtual storage access method (VSAM) processor of AR/CTL has detected an VSAM restart error. Processing terminates. User response: Check the AR/CTL messages issued during the job step for details about the cause of the error and the action to take. | ||||||||
U1776 | Explanation: AR/CTL detected that the application issued a DB2 request before connection to the Db2 subsystem was complete or that problems were encountered with the DB2 subsystem. AR/CTL issues a diagnostic message. Processing terminates. User response: Check the AR/CTL messages issued during the job step for details about the cause of the error and the action to take. | ||||||||
U1777 | Explanation: AR/CTL detected that the application issued a Db2 request but that no non-IMS program registration record, subsystem member, or DDITV02 statement was present. AR/CTL backs out uncommitted changes to application sequential access method (ASAM) data sets, issues message BMC74323, and abnormally terminates the job step with abend U1777 and reason code X'00074323'. User response: Provide the correct external subsystem connection parameters by supplying the subsystem member name in the parameter field of the EXEC statement or in a DD statement named DDITV02. | ||||||||
U1785 | Explanation: AR/CTL detected that the Automatic DB2 Cursor Repositioning option is set to Y, the Action for No Repositioning Record is set to ABEND, and a cursor repositioning record was not found for the cursor named in message BMC74361E. AR/CTL issues message BMC74361E. Processing terminates. User response: See message BMC74361E. | ||||||||
U1786 | Explanation: AR/CTL detected an error in the QUICKSTART for MVS-to-AR/CTL bridge. AR/CTL issues one or more accompanying error messages. Processing terminates. User response: See the accompanying messages. | ||||||||
U4016 | Explanation: The AR/CTL BCF component Log utility is executing on an unauthorized processor, or the trial period has expired. The job step terminates abnormally. User response: Correctly authorize the processor using the AR/CTL ISPF interface, or contact your BMC Software sales representative for assistance. | ||||||||
U4017 | Explanation: The AR/CTL BCF component Log utility detected a nonzero return code from an MVS system service. See message BMC48017I for additional information. The job step terminates abnormally. User response: Verify the existence of the data set associated with the ddname in message BMC48017I. Have the utility job log data set available if you need to contact BMC Customer Support for assistance. | ||||||||
U4018 | Explanation: The AR/CTL BCF component Log utility detected a nonzero return code from an MVS system service. See message BMC48018I for additional information. The job step terminates abnormally. User response: Verify the existence of the data set associated with the named DD statement. Have the utility job log data set available if you need to contact BMC Customer Support for assistance. | ||||||||
U4019 | Explanation: The AR/CTL BCF component Log utility detected a nonzero return code from an MVS system service. See message BMC48019I for additional information. The job step terminates abnormally. User response: Verify the existence of the data set associated with the named DD statement. Have the utility job log data set available if you need to contact BMC Customer Support for assistance. | ||||||||
U4020 | Explanation: The AR/CTL BCF component Log utility detected a nonzero return code from an MVS system service. See message BMC48020I for additional information. The job step terminates abnormally. User response: The control statement containing the request was printed to the SYSPRINT data set. Include the necessary DD statements in the job step JCL for proper utility execution. | ||||||||
U4025 | Explanation: The AR/CTL BCF component Log utility detected an invalid data set organization for one of the data sets used as input or output to the utility. See message BMC48025I for additional information. The job step terminates abnormally. User response: Correct the data set named in the message. Data sets used by the AR/CTL BCF component Log utility must have a physical sequential organization. | ||||||||
U4027 | Explanation: The AR/CTL BCF component Log utility OCREATE function received an incomplete request. See message BMC48027I for additional information. The job step terminates abnormally. User response: The OCREATE function must be provided with a unit of work (UOW) identifier representing the unique batch message processing program (BMP) execution desired. This is necessary to prevent incorrect extraction of update records for BMPs that are scheduled in parallel. Use the AR/CTL BCF component Log utility FIND function to obtain a list of program specification block (PSB) executions and the necessary UOW identifier. | ||||||||
U4033 | Explanation: The AR/CTL BCF component Log utility control statement processor detected an error in a control statement. See message BMC48033I for additional information. The job step terminates abnormally. User response: Correct the control statement in error. The control statement is listed following message BMC48033I. |