Specifying runtime data set information
To specify runtime data set information
On the Execute Project panel, from the list of configuration actions, select Set Runtime Data Set High Level Qualifiers and press Enter.
BMIPPRJE Execute Project
Command ===> _________________________________________________________________
Project Name . . . USER1
Description . . . Sandbox
JCL Data Set . . . USER1.BMCINST.JCLLIB
Select one of the following installation actions:
__ 1. Select Products, Solutions, or Infrastructure
2. Set SMP/E Data Set High Level Qualifiers
3. Set SMP/E Data Set Allocation Values
4. Set Installation Job Values and FTP Options
5. Generate and Execute Installation Batch Jobs
Select one of the following configuration actions:
__ 1. Set Runtime Data Set High Level Qualifiers
2. Set Runtime Data Set Allocation Values
3. Set Selected Product or Component Values
4. Set Configuration Job Values
5. Generate and Execute Configuration Batch Jobs
6. Multiple SSID install for DB2 Products only (optional)On the Runtime & Other Data Sets panel, specify the requested information, and press Enter.
BMIPCF10 USER1 - Runtime & Other Data Sets
Command ===> ________________________________________________ Scroll ===> CSR
Enter the Data Set HLQs for runtime data sets. Press enter after typing a value
in the Quick Fill to set the other HLQs. Enter a '/' in the Quick Clear field
to clear the HLQs.
Quick Clear. . . . . . . . . . . . _
Quick Fill . . . . . . . . . . . . ______________________________
Runtime Data Set HLQ (SMP/E content)
Product HLQ. . . . . . . . . . . ______________________________
Other Data Set HLQs (non-SMP/E content)
Product non-VSAM . . . . . . . . ______________________________
Product VSAM . . . . . . . . . . ______________________________
Low Level Qualifiers
Change Values. . . . . . . . 1 1. Use BMC* LLQs (recommended)
2. Use BB/DB/IM/XX LLQs
3. Customize the LLQs
Optional APF Load Library Must be a PDSE.
Existing Load Library . . .- In the Runtime Data Set HLQ and Other Data Set HLQs sections, specify HLQs.
- In the Change Values field in the Low Level Qualifiers section, select one of the following options for the low-level qualifiers (LLQs) for the product data sets:
Enter 1 to use BMC*.
(Recommended) All LLQs begin with BMC, followed by the type of library (such as LINK, SAMP, or PLIB). Examples are BMCLINK, BMCSAMP, and BMCPLIB. All products use the same set of libraries.
Enter 2 to use LLQs that start with product-line designators.
LLQs begin with one of the following designators, followed by the library type:
- BB for BMC AMI Ops and some performance products
- DB for BMC products for IBM Db2
- IM for BMC products for IBM IMS
- XX for Infrastructure components
For example, if you are installing a BMC product for IMS, the names would be IMLIB, IMSAMP, and IMPLIB. All products in the same product line use the same set of libraries.
If you already have BMC AMI Ops products installed, use this option to continue using the naming conventions of your existing libraries.
Enter 3 to specify your own LLQs as described in Step 3.
(Optional) In the Existing Load Library field, in the Optional APF Load Library section, specify an existing APF load library to use to consolidate all of the load libraries into one.
(If you selected option 3 for the LLQs) On the Product Runtime Data Set Low Level Qualifiers panel, view the data sets that will be created, customize the LLQs according to your preferences, and press Enter.
BMIPRTGR Product Runtime Data Set Low Level Qualifiers
Command ===> __________________________________________________________________
Verify Runtime data set Low Level Qualifiers. Press Enter to continue.
Data Set Target Default New
Type Suffix Suffix Suffix
----------------------- -------- -------- --------
CATALOG MGR DBRM LIB ACTDBRM BMCDBRM BMCDBRM
EXECUTION DBRM LIB AEXDBRM BMCDBRM BMCDBRM
HIGH SPEED APPLY LINK L APTLINK BMCLINK BMCLINK
DBC LINK LIB DBCLINK BMCLINK infLINK
XBM LINK LIB XBMLINK BMCLINK infLINK
POOL ADVISOR LINK LIBRA PMDLINK BMCLINK prfLINK
DB2 CMN UTILITY LINK LI D2ULINK BMCLINK BMCLINK
APPTUNE LINK LIB IODLINK BMCLINK prfLINK
WORKBENCH LINK LIB TARG GUDLINK BMCLINK BMCLINK
LGC TARGET LINK LIB LGCLINK BMCLINK infLINK
SAS 'C' RELATED DIGB4LB BMCLINK BMCLINK
MRE TARGET LINK LIBS MRELINK BMCLINK BMCLINK
SAS 'C' RELATED DIGBLB BMCLINK BMCLINK
COPY PLUS LINK LIB ACPLINK BMCLINK utlLINK
UNLOAD PLUS LINK LIB ADULINK BMCLINK utlLINKOn the Runtime Data Set Allocation Values panel, specify the allocation information for the runtime data sets and press Enter.
BMIPCF20 USER1 - Runtime Data Set Allocation Values
Command ===> ________________________________________________ Scroll ===> CSR
Enter the Allocation Values for the runtime data sets. SMS values will be used
if specified. Press enter after entering a value in the Quick Fill to set the
other Allocation Values. Enter a '/' in the Quick Clear fields to clear the
values in that column.
Quick Clear . . . . . . . . . . _ _ _ _ _
Quick Fill . . . . . . . . . . ________ ________ ________ ________ ______
Data Set Type STORCLAS MGMTCLAS DATACLAS UNIT VOLSER
Product Runtime Data Sets ________ ________ ________ SYSALLDA ______
Product non-VSAM Data Sets ________ ________ ________ SYSALLDA ______
Product VSAM Data Sets ________ ________ ________ SYSALLDA ______
Product PDSE Data Sets ________ ________ ________ SYSALLDA ______You can specify SMS information or VOLSER information for the data sets. If you specify both, the Installation System uses the SMS information.
Where to go from here
Continue to Specifying-product-configuration-information.
For more information, view the Quick Course Installation System - Runtime Library Options. Note: You must already be logged into BMC Support Central or you will receive a Page Not Found error. For a list of Quick Courses about the Installation System, see PDFs-and-videos. |