Control-M/EM PANFT.9.0.21.302


BMC Software is releasing Control-M/EM patch PANFT.9.0.21.302, which corrects the following problems in Control-M/EM on Linux and Windows.

Information
Important

Verify that Control-M/EM 9.0.21.300 is installed before you install this patch.

Corrected Problems

The following table describes the problems that are corrected in Control-M/EM PANFT.9.0.21.302.

Tracking NumberDescription

CTM-11711

The Configuration Management Server (CMS) and GUI Server has a memory leak that causes memory usage to slowly increase.

CTM-11657

The Configuration Management Server (CMS) and the GUI Server experience performance issues in a Control-M environment with an extremely large number of users. 

CTM-10350

Synchronization of connection profiles between Control-M/EM and the Control-M/Servers is slow or fails and, as a result, jobs fail. This occurs when a large number of centralized connection profiles are defined.

 Installing Control-M/EM Patch PANFT.9.0.21.302 on Linux

This procedure describes how to install Control-M/EM patch PANFT.9.0.21.302 on Linux.

Information
Important

You must install this patch on every host where Control-M/EM server is installed.

Before You Begin

  • Verify that Control-M/EM 9.0.21.300 is installed before you apply this patch. 

Begin

  1. Download the installation package from Control-M/EM 9.0.21 Patches.
  2. Log in to the account where Control-M/EM is installed, copy the installation package to a temporary directory on your local hard drive (not a network drive), and then extract the package.
  3. Set execution flags for the patch installation file using the following command:
    chmod +x <temporary directory>/PANFT.9.0.21.302_
    Linux-x86_64_INSTALL.BIN
  4. Stop all Control-M/EM components.
  5. Run the following script from the Control-M/EM Home directory:
    <temporary directory>/PANFT.9.0.21.302_Linux-x86_64_INSTALL.BIN
  6. Follow the on-screen instructions until the installation is complete.
  7. Start all Control-M/EM components.

Installing Control-M/EM Patch PANFT.9.0.21.302 on Windows

This procedure describes how to install Control-M/EM patch PANFT.9.0.21.302 on Windows.

Information
Important

You must install this patch on every host where Control-M/EM server is installed.

Before You Begin

  • Verify that Control-M/EM version 9.0.21.300 is installed before you apply this patch. 

Begin

  1. Download the installation package from Control-M/EM 9.0.21 Patches.
  2. Log in to the account where Control-M/EM is installed, copy the installation package to a temporary directory on your local hard drive (not a network drive), and then extract the package.
  3. Stop all Control-M/EM components.
  4. Double-click the PANFT.9.0.21.302_windows_x86_64.exe file.
  5. Follow the on-screen instructions until the installation is complete.
  6. Start all Control-M/EM components.

Uninstalling Control-M/EM Patch PANFT.9.0.21.302 from Linux

This procedure describes how to uninstall Control-M/EM patch PANFT.9.0.21.302 from Linux. 

Begin

  1. Stop all Control-M/EM components.
  2. Navigate to the following directory:
    <USER_HOME>/install/PANFT.9.0.21.302 
  3. Run the following script:
    uninstall.sh
  4. Start all Control-M/EM components.

Uninstalling Control-M/EM Patch PANFT.9.0.21.302 from Windows

This procedure describes how to uninstall Control-M/EM patch PANFT.9.0.21.302 from Windows. 

Begin

  1. Stop all Control-M/EM components.
  2. From Windows Settings > Apps > Apps & Features, select Control-M/Enterprise Manager 9.0.21.300 patch 2 (<instance name>).
  3. Select Uninstall.
  4. Start all Control-M/EM components.

 

Tip: For faster searching, add an asterisk to the end of your partial query. Example: cert*