Control-M/EM PANFT.9.0.21.002


BMC Software is releasing Control-M/EM patch PANFT.9.0.21.002, which corrects the following problems in Control-M/EM on UNIX and Windows.

Information
Important

Verify that Control-M/EM 9.0.21.200 and PANFT.9.0.21.201 are installed before you install this patch. This patch is cumulative. You do not need to install previous patches.

Corrected Problems

The following table describes the problems that are corrected in Control-M/EM PANFT.9.0.21.002.

Tracking NumberPatchDescription

CTM-4521

PANFT.9.0.21.002

The Service tab in the Monitoring domain becomes inactive after a period of idle time.

CTM-7472 

PANFT.9.0.21.002

The Run as User Enter Password field in the Run as Users Authentication Settings window in the CCM remains empty and when trying to update causes all jobs that run by this user to fail when Compatibility mode is on.

CTM-7494

PANFT.9.0.21.002

The following issues are detected in NodeJs:

  • CVE-2022-32215
  • CVE-2022-32214
  • CVE-2022-32213

CTM-7418

PANFT.9.0.21.002

The periodic calendar does not properly appear in View Schedule in Control-M Web when the first period does not start on the first day of the month.

CTM-7498

PANFT.9.0.21.002

The wrong report in the Folder Manager might run when the browser language is set to United Kingdom English.

CTM-7465

PANFT.9.0.21.002

The following error message appears in Automation API when you run a Jobs Definitions category report:
Failed to run report Jobs Definitions - Events_1.

CTM-7416

PANFT.9.0.21.002

Issue CVE-2022-37614 is detected in the Control-M command line interface.

CTM-7496

PANFT.9.0.21.002

Security vulnerability CVE-2022-7501 is detected in Control-M/EM.

CTM-7398

PANFT.9.0.21.002

A search in Control-M Workload Archiving 9.0.21.000 does not return all rows of job logs for cyclic jobs with a rerun count greater than 5.

To resolve this issue, you must apply Control-M/Server patch PACTV.9.0.21.002.

CTM-7386

PANFT.9.0.21.002

SSL encryption might not work after you upgrade Control-M/EM 9.0.20 to 9.0.21 in a One Install configuration. 

CTM-7500

PANFT.9.0.21.002

Vulnerabilities are detected in the ESS package password (bmcryptpw utility).

CTM-7443

PANFT.9.0.21.001

Security vulnerability CVE-2022-42889 detected in a library used by Control-M/EM services.

CTM-7431

PANFT.9.0.21.001

If you run an ad hoc job in a folder that contains more than 10 jobs, a different job from the same folder might be run. This occurs if Control-M/EM and Control-M/Server are both version 9.0.21.

CTM-7430

PANFT.9.0.21.001

Permissions for the following actions on services in the Monitoring domain are not enforced correctly:

  • Drill-Down
  • Run 
  • Hold
  • Resume
  • View orderable services that were started by other users

CTM-7424

PANFT.9.0.21.001

Usage report data might not be collected by the Configuration Management Server (CMS).

CTM-7434

PANFT.9.0.21.001

Days in a periodic calendar or regular calendar are incorrect or are shifted by one day when you use the recurrence option to mark weekdays and the language in the browser is not US English.

CTM-7361

PANFT.9.0.21.001

The tree in the navigation pane of a viewpoint in Control-M Web is displayed with incorrect hierarchy when you open a viewpoint with non-default grouping and grouping is turned on.

 Installing Control-M/EM Patch PANFT.9.0.21.002 on UNIX

This procedure describes how to install Control-M/EM patch PANFT.9.0.21.002 on UNIX.

Information
Important

You must install this patch on every host where Control-M client is installed.

Before You Begin

  • Verify Control-M/EM version 9.0.21.000 is installed. 

Begin

  1. Download the installation package from Control-M/EM 9.0.21 Patches.
  2. Log in to the account where Control-M/EM is installed, copy the installation package to a temporary directory on your local hard drive (not a network drive), and then extract the package.
  3. Set execution flags for the patch installation file using the following command:
    chmod +x PANFT.PANFT.9.0.21.002_<platform>_INSTALL.BIN
  4. Stop all Control-M/EM components.
  5. Run the following script from the Control-M/EM Home directory:
    <temporary directory>/PANFT.9.0.21.002_<platform>_INSTALL.BIN
  6. Follow the on-screen instructions until the installation is complete.
  7. Start all Control-M/EM components.

Installing Control-M/EM Patch PANFT.9.0.21.002 on Windows

This procedure describes how to install Control-M/EM patch PANFT.9.0.21.002 on Windows.

Information
Important

You must install this patch on every host where Control-M client is installed.

Before You Begin

  • Verify Control-M/EM version 9.0.21.000 is installed. 

Begin

  1. Download the installation package from Control-M/EM 9.0.21 Patches.
  2. Log in to the account where Control-M/EM is installed, copy the installation package to a temporary directory on your local hard drive (not a network drive), and then extract the package.
  3. Stop all Control-M/EM components.
  4. Double-click the downloaded patch installation file.
  5. Follow the on-screen instructions until the installation is complete.
  6. Start all Control-M/EM components.

Installing Control-M/EM Patch PANFT.9.0.21.002 via Client Distribution on UNIX

This procedure describes how to install Control-M/EM patch PANFT.9.0.21.002 via Client Distribution on UNIX.

Begin

  1. From the Control-M/Enterprise Manager server computer, navigate to the BIN directory:
    cd $EM_HOME%/bin
  2. Run the following utility:
    em deploy_client_patch -U <EM USER> -P <EM PASSWORD> <PATH_TO_TEMPORARY_DIRECTORY_WHERE_PATCH_WAS_DOWNLOADED>/PANFT.9.0.21.002
  3. Log in to the CCM, and set the patch for deployment.
    1. From the Manage tab, click Client Distribution.
    2. Select the Fix Packs tab.
    3. Select PANFT.9.0.21.002.

When the end user logs in to the Control-M client, a notification appears instructing the user to install the patch.

Installing Control-M/EM Patch PANFT​​​​​​​.9.0.21.002 via Client Distribution on Windows

This procedure describes how to install Control-M/EM patch PANFT.9.0.21.002 via Client Distribution on Windows.

Begin

  1. From the Control-M/Enterprise Manager server computer, navigate to the BIN directory:
    cd %EM_HOME%\bin
  2. Run the following utility:
    deploy_client_patch.bat -U -P \ <EM USER> -P <EM PASSWORD> <PATH_TO_TEMPORARY_DIRECTORY_WHERE_PATCH_WAS_DOWNLOADED>PANFT.9.0.21.002_windows_x86_64.exe64-bit Example:
    deploy_client_patch.bat -U emuser -P myPassword C:\PANFT.9.0.21.002\PANFT.9.0.21.002_windows_x86_64.exe
  3. Log in to the CCM, and set the patch for deployment.
    1. From the Manage tab, click Client Distribution.
    2. Select the Fix Packs tab.
    3. Select PANFT.9.0.21.002.

When the end user logs in to the Control-M client, a notification appears instructing the user to install the patch.

Uninstalling Control-M/EM Patch PANFT.9.0.21.002 from UNIX

This procedure describes how to uninstall Control-M/EM patch PANFT.9.0.21.002 from UNIX.

Begin

  1. Stop all Control-M/EM components.
  2. Navigate to the following directory:
    <USER_HOME>/install/PANFT.9.0.21.002 
  3. Run the following script:
    uninstall.sh
  4. Start all Control-M/EM components.

Uninstalling Control-M/EM Patch PANFT.9.0.21.002 from Windows

This procedure describes how to uninstall Control-M/EM patch PANFT.9.0.21.002 from Windows.

Begin

  1. Stop all Control-M/EM components.
  2. From Windows Settings > Apps > Apps & Features, select Control-M/Enterprise Manager PANFT.9.0.21.002 (<instance name>).
  3. Select Uninstall.
  4. Start all Control-M/EM components.

 

Tip: For faster searching, add an asterisk to the end of your partial query. Example: cert*

Control-M 9.0.21