Control-M/EM PANFT.9.0.21.002
BMC Software is releasing Control-M/EM patch PANFT.9.0.21.002, which corrects the following problems in Control-M/EM on UNIX and Windows.
Corrected Problems
The following table describes the problems that are corrected in Control-M/EM PANFT.9.0.21.002.
| Tracking Number | Patch | Description |
|---|---|---|
CTM-4521 | PANFT.9.0.21.002 | The Service tab in the Monitoring domain becomes inactive after a period of idle time. |
CTM-7472 | PANFT.9.0.21.002 | The Run as User Enter Password field in the Run as Users Authentication Settings window in the CCM remains empty and when trying to update causes all jobs that run by this user to fail when Compatibility mode is on. |
CTM-7494 | PANFT.9.0.21.002 | The following issues are detected in NodeJs:
|
CTM-7418 | PANFT.9.0.21.002 | The periodic calendar does not properly appear in View Schedule in Control-M Web when the first period does not start on the first day of the month. |
CTM-7498 | PANFT.9.0.21.002 | The wrong report in the Folder Manager might run when the browser language is set to United Kingdom English. |
CTM-7465 | PANFT.9.0.21.002 | The following error message appears in Automation API when you run a Jobs Definitions category report: |
CTM-7416 | PANFT.9.0.21.002 | Issue CVE-2022-37614 is detected in the Control-M command line interface. |
CTM-7496 | PANFT.9.0.21.002 | Security vulnerability CVE-2022-7501 is detected in Control-M/EM. |
CTM-7398 | PANFT.9.0.21.002 | A search in Control-M Workload Archiving 9.0.21.000 does not return all rows of job logs for cyclic jobs with a rerun count greater than 5. To resolve this issue, you must apply Control-M/Server patch PACTV.9.0.21.002. |
CTM-7386 | PANFT.9.0.21.002 | SSL encryption might not work after you upgrade Control-M/EM 9.0.20 to 9.0.21 in a One Install configuration. |
CTM-7500 | PANFT.9.0.21.002 | Vulnerabilities are detected in the ESS package password (bmcryptpw utility). |
CTM-7443 | PANFT.9.0.21.001 | Security vulnerability CVE-2022-42889 detected in a library used by Control-M/EM services. |
CTM-7431 | PANFT.9.0.21.001 | If you run an ad hoc job in a folder that contains more than 10 jobs, a different job from the same folder might be run. This occurs if Control-M/EM and Control-M/Server are both version 9.0.21. |
CTM-7430 | PANFT.9.0.21.001 | Permissions for the following actions on services in the Monitoring domain are not enforced correctly:
|
CTM-7424 | PANFT.9.0.21.001 | Usage report data might not be collected by the Configuration Management Server (CMS). |
CTM-7434 | PANFT.9.0.21.001 | Days in a periodic calendar or regular calendar are incorrect or are shifted by one day when you use the recurrence option to mark weekdays and the language in the browser is not US English. |
CTM-7361 | PANFT.9.0.21.001 | The tree in the navigation pane of a viewpoint in Control-M Web is displayed with incorrect hierarchy when you open a viewpoint with non-default grouping and grouping is turned on. |
Installing Control-M/EM Patch PANFT.9.0.21.002 on UNIX
This procedure describes how to install Control-M/EM patch PANFT.9.0.21.002 on UNIX.
Before You Begin
- Verify Control-M/EM version 9.0.21.000 is installed.
Begin
- Download the installation package from Control-M/EM 9.0.21 Patches.
- Log in to the account where Control-M/EM is installed, copy the installation package to a temporary directory on your local hard drive (not a network drive), and then extract the package.
- Set execution flags for the patch installation file using the following command:
chmod +x PANFT.PANFT.9.0.21.002_<platform>_INSTALL.BIN - Stop all Control-M/EM components.
- Run the following script from the Control-M/EM Home directory:
<temporary directory>/PANFT.9.0.21.002_<platform>_INSTALL.BIN - Follow the on-screen instructions until the installation is complete.
- Start all Control-M/EM components.
Installing Control-M/EM Patch PANFT.9.0.21.002 on Windows
This procedure describes how to install Control-M/EM patch PANFT.9.0.21.002 on Windows.
Before You Begin
- Verify Control-M/EM version 9.0.21.000 is installed.
Begin
- Download the installation package from Control-M/EM 9.0.21 Patches.
- Log in to the account where Control-M/EM is installed, copy the installation package to a temporary directory on your local hard drive (not a network drive), and then extract the package.
- Stop all Control-M/EM components.
- Double-click the downloaded patch installation file.
- Follow the on-screen instructions until the installation is complete.
- Start all Control-M/EM components.
Installing Control-M/EM Patch PANFT.9.0.21.002 via Client Distribution on UNIX
This procedure describes how to install Control-M/EM patch PANFT.9.0.21.002 via Client Distribution on UNIX.
Begin
- From the Control-M/Enterprise Manager server computer, navigate to the BIN directory:
cd $EM_HOME%/bin - Run the following utility:
em deploy_client_patch -U <EM USER> -P <EM PASSWORD> <PATH_TO_TEMPORARY_DIRECTORY_WHERE_PATCH_WAS_DOWNLOADED>/PANFT.9.0.21.002 - Log in to the CCM, and set the patch for deployment.
- From the Manage tab, click Client Distribution.
- Select the Fix Packs tab.
- Select PANFT.9.0.21.002.
When the end user logs in to the Control-M client, a notification appears instructing the user to install the patch.
Installing Control-M/EM Patch PANFT.9.0.21.002 via Client Distribution on Windows
This procedure describes how to install Control-M/EM patch PANFT.9.0.21.002 via Client Distribution on Windows.
Begin
- From the Control-M/Enterprise Manager server computer, navigate to the BIN directory:
cd %EM_HOME%\bin - Run the following utility:
deploy_client_patch.bat -U -P \ <EM USER> -P <EM PASSWORD> <PATH_TO_TEMPORARY_DIRECTORY_WHERE_PATCH_WAS_DOWNLOADED>PANFT.9.0.21.002_windows_x86_64.exe64-bit Example:
deploy_client_patch.bat -U emuser -P myPassword C:\PANFT.9.0.21.002\PANFT.9.0.21.002_windows_x86_64.exe - Log in to the CCM, and set the patch for deployment.
- From the Manage tab, click Client Distribution.
- Select the Fix Packs tab.
- Select PANFT.9.0.21.002.
When the end user logs in to the Control-M client, a notification appears instructing the user to install the patch.
Uninstalling Control-M/EM Patch PANFT.9.0.21.002 from UNIX
This procedure describes how to uninstall Control-M/EM patch PANFT.9.0.21.002 from UNIX.
Begin
- Stop all Control-M/EM components.
- Navigate to the following directory:
<USER_HOME>/install/PANFT.9.0.21.002 - Run the following script:
uninstall.sh - Start all Control-M/EM components.
Uninstalling Control-M/EM Patch PANFT.9.0.21.002 from Windows
This procedure describes how to uninstall Control-M/EM patch PANFT.9.0.21.002 from Windows.
Begin
- Stop all Control-M/EM components.
- From Windows Settings > Apps > Apps & Features, select Control-M/Enterprise Manager PANFT.9.0.21.002 (<instance name>).
- Select Uninstall.
- Start all Control-M/EM components.