Updating the Web Server HTTPS port


Do the following:

  1. Stop the following services:
    • TrueSight Server Automation - Data Warehouse Web server service 
    •  TrueSight Smart Reporting service
  2. Edit the following files and change the default port.
    • <TSSA-DWInstallationDirectory>\TSSA-DW\tomcat\conf\server.xml
    • <TSSA-DWInstallationDirectory>\TSSA-DW\BdssaInstalledConfiguration.xml
    • <TSSA-DWInstallationDirectory>\TSSA-DW\shared\ConfigurationManagement\bds.properties
  3. Save the files.
  4. Start the following services:
    • TrueSight Server Automation - Data Warehouse Web server service 
    •  TrueSight Smart Reporting service
  5. Verify that you can launch the TrueSight Server Automation - Data Warehouse console with the new port number.
  6. If TrueSight Smart Reporting - Platform is already added as a component, modify TrueSight Server Automation - Data Warehouse component information in TrueSight Smart Reporting - Platform.
    Do the following:
    1. Use the following URL to open the Login page:
      https://<TrueSight Smart Reporting hostname>:<port>/tsr
    2. In the Log in as field, select TrueSight Smart Reporting - Admin.
    3. Enter the TrueSight Smart Reporting - Platform administrator user name and password, and click Login. The Components page appears.
    4. Click the Edit icon edit_component_icon.png for the component that you want to edit.
    5. In the Edit Component page, modify the values of the component. Ensure that you add correct details while editing a component to avoid errors.
    6. Click Save to save your changes.
  7. Verify that you can launch the reports successfully.




 