Known and corrected issues
Related topics
Release notes and notices
Troubleshooting
Review the following tables for issues that were corrected in TrueSight Server Automation 25.4 and for known issues that remain open. The product refers to TrueSight Server Automation, unless stated otherwise.
Corrected issues | View the issues in the following tables by the default sort order, Corrected in , which shows the corrected issues first. The version number represents the update ( Year.Month.Release ) or release number (MajorRelease.MinorRelease.ServicePack.Patch) in which the issue is fixed. |
|---|---|
Known (open) issues | To view only the open issues, click the Corrected in filter, and select empty . An issue without a value for Corrected in remains open. |
You can also filter and sort issues according to affected version (versions in which the issue exists), component, or defect ID.
Corrected issues in TrueSight Server Automation
Defect ID | Component | Description | Affected versions | Corrected in |
|---|---|---|---|---|
| DRBLG-152246 | RSCD Agent | Symptom: RSCD agent deployment fails or creates an unwanted file when the staging path contains spaces because the process does not handle spaces correctly. | 24.2.00, 24.4.00, 25.2.00 | 25.4.00 |
| DRBLG-152525 | Application Server | Symptom: An unexpected, additional string appears in Process Explorer when viewing BSAClient.exe properties, showing internal source and build directory information. | 23.1.00, 23.2.00,23.4.00, 24.2.00, 24.4.00, 25.2.00 | 25.4.00 |
| DRBLG-152056 | RBAC | Symptom: In TSSA 24.4.01.59, opening RBAC Roles under RBAC Manager is slow or fails, leaving the tab empty and freezing the console. | 24.4.00, 25.2.00 | 25.4.00 |
| DRBLG-152915 | Patch Management | Symptom: The rpmlinux_downloader.sh -listChannels command lists channels but suggests URLs that don't work in the offline patch catalog XML for Rocky Linux. | 24.2.00, 24.4.00, 25.2.00 | 25.4.00 |
| DRBLG-152403 | Upgrade | Symptom: The UPI-based upgrade from TSSA 24.2 to 24.4 P1 completes with a warning because it throws a NullPointerException while updating an NSH script, causing the command to fail. | 24.2.00, 24.4.00, 25.2.00 | 25.4.00 |
| DRBLG-152404 | Upgrade | Symptom: During upgrade from TSSA 24.2 GA to 24.4 P1, UPI logs an error in bsainstallupgrade.log as it uses the /etc/init.d/blappserv script instead of systemctl to manage the application. | 24.2.00, 24.4.00, 25.2.00 | 25.4.00 |
| DRBLG-152445 | Patch Management | Symptom: HP-UX VPC patching fails during analysis, download, and packaging because the script does not handle file paths correctly. | 25.2.00 | 25.4.00 |
| DRBLG-153169 | Patch Management | Symptom: Patching download job run logs are deleted within the retention period after running offline cleanup, even though the logs are still present on the application server physically. | 24.2.00, 24.4.00, 25.2.00 | 25.4.00 |
| DRBLG-152705 | Server | Symptom: The TSSA console shows a blank packaging date for IPS packages on Solaris 11 servers instead of displaying the date for the last patch | 23.4.00, 24.2.00, 24.4.00, 25.2.00 | 25.4.00 |
| DRBLG-152400 | Deployment | Symptom: When adding a new application server via Add Node, the deployment sets useSSLSocket=true by default, ignoring existing server settings. This causes the new server to appear down or unreachable in the console. | 24.2.00, 24.4.00, 25.2.00 | 25.4.00 |
| DRBLG-152743 | Compliance | Symptom: Exported compliance data displays the actual value multiple times when viewed in a browser instead of showing a single entry. | 24.4.00, 25.2.00 | 25.4.00 |
BMC Confidential. The preceding information is intended only for registered users of docs.bmc.com.
Open issues in TrueSight Server Automation