Known and corrected issues


Review the following tables for issues that were corrected in TrueSight Server Automation 25.4 and for known issues that remain open. The product refers to TrueSight Server Automation, unless stated otherwise.

Corrected issues

View the issues in the following tables by the default sort order, Corrected in , which shows the corrected issues first. 

The version number represents the update ( Year.Month.Release ) or release number (MajorRelease.MinorRelease.ServicePack.Patch) in which the issue is fixed.

Known (open) issues

To view only the open issues, click the  Corrected in  filter, and select  empty . An issue without a value for  Corrected in  remains open.

You can also filter and sort issues according to affected version (versions in which the issue exists), component, or defect ID.

Corrected issues in TrueSight Server Automation

Defect ID

Component

Description

Affected versions

Corrected in

DRBLG-152246RSCD AgentSymptom: RSCD agent deployment fails or creates an unwanted file when the staging path contains spaces because the process does not handle spaces correctly.24.2.00, 24.4.00, 25.2.0025.4.00
DRBLG-152525Application ServerSymptom: An unexpected, additional string appears in Process Explorer when viewing BSAClient.exe properties, showing internal source and build directory information. 23.1.00, 23.2.00,23.4.00, 24.2.00, 24.4.00, 25.2.0025.4.00
DRBLG-152056RBACSymptom: In TSSA 24.4.01.59, opening RBAC Roles under RBAC Manager is slow or fails, leaving the tab empty and freezing the console.24.4.00, 25.2.0025.4.00
DRBLG-152915Patch ManagementSymptom: The rpmlinux_downloader.sh -listChannels command lists channels but suggests URLs that don't work in the offline patch catalog XML for Rocky Linux.24.2.00, 24.4.00, 25.2.0025.4.00
DRBLG-152403UpgradeSymptom: The UPI-based upgrade from TSSA 24.2 to 24.4 P1 completes with a warning because it throws a NullPointerException while updating an NSH script, causing the command to fail.24.2.00, 24.4.00, 25.2.0025.4.00
DRBLG-152404Upgrade

Symptom: During upgrade from TSSA 24.2 GA to 24.4 P1, UPI logs an error in bsainstallupgrade.log as it uses the /etc/init.d/blappserv script instead of systemctl to manage the application.

24.2.00, 24.4.00, 25.2.0025.4.00
DRBLG-152445Patch Management

Symptom: HP-UX VPC patching fails during analysis, download, and packaging because the script does not handle file paths correctly.

25.2.0025.4.00
DRBLG-153169Patch ManagementSymptom: Patching download job run logs are deleted within the retention period after running offline cleanup, even though the logs are still present on the application server physically.24.2.00, 24.4.00, 25.2.0025.4.00
DRBLG-152705ServerSymptom: The TSSA console shows a blank packaging date for IPS packages on Solaris 11 servers instead of displaying the date for the last patch23.4.00, 24.2.00, 24.4.00, 25.2.0025.4.00
DRBLG-152400DeploymentSymptom: When adding a new application server via Add Node, the deployment sets useSSLSocket=true by default, ignoring existing server settings. This causes the new server to appear down or unreachable in the console.24.2.00, 24.4.00, 25.2.0025.4.00
DRBLG-152743ComplianceSymptom: Exported compliance data displays the actual value multiple times when viewed in a browser instead of showing a single entry.24.4.00, 25.2.0025.4.00

 

 

 

 

BMC Confidential. The preceding information is intended only for registered users of docs.bmc.com.

 

 

 

 

Open issues in TrueSight Server Automation

Error

You must log in or register to view this page

 

 

Tip: For faster searching, add an asterisk to the end of your partial query. Example: cert*