Issues table


Corrected issues in TrueSight Server AutomationEdit

Defect ID

Component

Description

Affected versions

Corrected in

DRBLG-152246RSCD Agent

Symptom: Configuring the staging directory to any path causes the deployment to fail with an error.

Workaround: Set the staging path to the default /temp/stage or to a path that does not contain spaces.

24.2.00
24.4.00
25.2.00
25.4.00
DRBLG-152525Application ServerSymptom: In Process Explorer, an unexpected, additional string appears in the properties of the SAClient.exe file. 23.1.00 23.2.00
23.4.00 24.2.00 24.4.00 25.2.00
25.4.00
DRBLG-152056RBACSymptom: An RBAC role under the Roles folder in RBAC Manager might take a long time to open or might fail to open.24.4.00 25.2.0025.4.00
DRBLG-152915Patch ManagementSymptom: The rpmlinux_downloader.sh -listChannels command lists channels but suggests URLs that don't work in the offline patch catalog XML for Rocky Linux.24.2.00 24.4.00 25.2.0025.4.00
DRBLG-152403Upgrade

Symptom: The UPI-based upgrade from TrueSight Server Automation version 24.2 to 24.4.01 completes with the following NullPointerException:

Error Console while running command null],Detail=[Picked up _JAVA_OPTIONS: -Djava.io.tmpdir=/opt/SP/app/Store/Appserver_Install Command execution failed. com.bladelogic.om.infra.mfw.util.BlException: Unexpected exception while handling request.com.bladelogic.om.infra.app.api.NSHScriptService_saveAndCopy(com.bladelogic.om.infra.model.depot.script.NSHScript, java.lang.String): java.lang.NullPointerException ]}

24.2.00 24.4.00 25.2.0025.4.00
DRBLG-152404Upgrade

Symptom: The UPI-based upgrade from TrueSight Server Automation version 24.2 GA to 24.4 Patch 1 on Linux 9 with an Oracle 19c database logs the following error in the bsainstallupgrade.log file:

Error while running command /etc/init.d/blappserv stop
Cannot run program "/etc/init.d/blappserv": error=2, No such file or directory

24.2.00 24.4.00 25.2.0025.4.00
DRBLG-152445Patch Management

Symptom: HP-UX VPC patching fails during analysis, download, and packaging.

25.2.0025.4.00
DRBLG-153169Patch ManagementSymptom: The offline database cleanup utility deletes the pathing download job run logs even though they are within the retention period and present on the application server. 24.2.00 24.4.00 25.2.0025.4.00
DRBLG-152705ServerSymptom: The TrueSight Server Automation console shows a blank packaging date for IPS packages on Solaris 11 servers instead of displaying the date of last patching.23.4.00 24.2.00 24.4.00 25.2.0025.4.00
DRBLG-152400DeploymentSymptom: When you add a new application server by using the Add Node option, the deployment settings for the existing application server and sets the useSSLSocket to true by default. This causes the new server to appear down or unreachable in the console.24.2.00 24.4.00 25.2.0025.4.00
DRBLG-152743ComplianceSymptom: Exported compliance data displays the actual value multiple times when viewed in a browser instead of showing a single entry.24.4.00 25.2.0025.4.00

 

 

 

Tip: For faster searching, add an asterisk to the end of your partial query. Example: cert*

TrueSight Server Automation 25.4